NF5688M6 Components: Front and Rear Views, LEDs and Drawer Removal

This article follows the numbered drawings in the stored source. The official English NF5688M6 White Paper V1.0 uses different callout numbering in some drawings: its front-view items 1/2 and its power/fan LED item order differ. Use the table paired with the displayed figure; do not transfer numbers from another revision. The unannotated numbered diagrams themselves need no language replacement.

1. Views

1.1 Front view: sixteen 2.5-inch drives

Original language-neutral 16-drive front drawing with callouts1through17
Callout in this drawingComponent
1Motherboard drawer handles ×2
2OCP3.0 module
3PCIe card area, up to 6 cards
4System serial port
5BMC serial port
6BMC management network port
7VGA port
8USB3.0 port
9USB2.0/LCD port
10Rack-transport screw covers ×4
11Drive module, 16 bays
12Server-to-rack retaining latches ×2
13GPU-module drawer handles ×2
14Switch drawer handles ×2
15UID/BMC RST button
16Indicator LEDs
17Power button and LED

Front view: eight 2.5-inch drives

Original language-neutral 8-drive front drawing with callouts18and19
CalloutComponent
18Drive module, 8 bays
19PCIe card area, up to 12 cards

1.2 Rear view

Original language-neutral rear drawing with six PSUs and twelve fans
CalloutComponent
1Power supply units ×6
2Fan modules ×12
3VGA port
4USB3.0 port

1.3 Front-panel buttons and LEDs

Source itemIconButton or indicatorMeaning
1
Original Power button and LED symbol
Power button and LEDOff: no power; solid green: powered on; solid orange: standby. From power-on, hold 4 seconds to force shutdown; follow the OS shutdown procedure for a normal shutdown. In standby, a short press powers on.
2
Original System fault LED symbol
System fault LEDOff: normal; flashing red at 1Hz: general/non-critical warning; solid red: severe/critical warning.
3
Original Memory fault LED symbol
Memory fault LEDOff: normal; flashing red at 1Hz: general/non-critical warning; solid red: severe/critical warning.
4
Original Fan fault LED symbol
Fan fault LEDOff: normal; flashing red at 1Hz: general/non-critical warning; solid red: severe/critical warning.
5
Original Power fault LED symbol
Power fault LEDOff: normal; flashing red at 1Hz: general/non-critical warning; solid red: severe/critical warning.
6
Original System overtemperature LED symbol
System overtemperature LEDOff: normal cooling status; flashing red at 1Hz: general/non-critical thermal warning; solid red: severe/critical warning.
7
Original Network status LED symbol
Network status LEDThe source says no onboard LAN is provided for this indication, so the function does not illuminate. This does not mean the separate BMC management port or installed OCP NIC is absent.
8
Original UID/RST button and LED symbol
UID/RST button and LEDOff: not located; solid blue: located; flashing blue: remote operation. The UID button or ISBMC can turn the identification LED on/off. Holding the button for more than 6 seconds resets the BMC.

A forced shutdown and BMC reset are distinct disruptive actions, not the normal short-press UID locate operation. Interpret LEDs together with the actual management/log information.

Drive-carrier indicators

Original drive-carrier illustration identifying activity LED1and fault/location/rebuild LED2
CalloutIndicatorSource states
1Drive activitySolid green: normal; flashing green: read/write activity.
2Drive fault/statusSolid red: drive fault; solid blue: drive location; solid pink: RAID drive rebuild.

2. Chassis

2.1 Removing the modules

Use the applicable service preparation, power-isolation and handling procedure; these drawers are not identified here as hot-swappable. Support each drawer’s weight and protect the internal connectors. The source’s illustrated removal actions are:

1. Loosen the retaining screws for the motherboard, switch or GPU-module drawer, as shown by callout 1:

Original screw-release drawing with callout1

2. Open both motherboard drawer handles in direction 2. Hold the handles and pull the motherboard drawer out in direction 3:

Original motherboard-drawer removal drawing with handle arrows2and withdrawal arrow3

3. Open the switch drawer handles in direction 4. Hold them and withdraw the switch drawer in direction 5:

Original switch-drawer removal drawing with handle arrows4and withdrawal arrow5

4. Open the GPU-module drawer handles in direction 6 and pull in direction 7. When the side release buttons become exposed, press and hold both buttons as shown by callout 8 and continue withdrawing the drawer:

Original GPU-module drawer drawing with handle6, withdrawal7and both release buttons8

2.2 Motherboard-module top cover

The stored source ends at this heading without a cover-removal procedure or additional diagram. Do not infer screw positions or a release sequence from the drawer figures; use the correct service-manual revision for that operation.

References

Can't find an answer?