BMC Web UI
- PM8204/PM8254 RAID on M6 BMC: JBOD, RAID Creation and Deletion
- LSI 9361-8i RAID on M6 BMC: JBOD, RAID0/RAID1/RAID5 and Deletion
- LSI 9361-8i: Configure RAID through the M5 BMC
Legacy Mode
- MegaRAID Ctrl-R: RAID, JBOD, Spares and Recovery Examples
- Configure and Inspect Legacy MegaRAID WebBIOS with Ctrl+H
- LSI SAS Ctrl+C Utility: RAID0, RAID1, RAID1E, Spares and Maintenance
- Intel SATA RAID with Ctrl+I: Configuration, Status and Recovery Examples
- LSI 1068E Ctrl+M Software RAID: Configuration, Spares and Recovery Examples
- 9230 SATA M.2 RAID in Legacy BIOS: Ctrl+M Configuration and Rebuild Status
- Configure Adaptec 6805 and PMC PM8060/8068 RAID with Ctrl+A
- Configure PM8222/PM8204 Controllers with the Ctrl+A Legacy Utility
NVMe Arrays
- Four-Socket NVMe RAID with Intel VROC: Socket Mapping and RAID0/1/5/10
- Two-Socket NVMe RAID with Intel VROC: VMD Setup, Arrays, Spares and Rebuilds
OS Command Line
- SAS3IRCU Reference for SAS3008: Inventory, IR Volumes, Spares and Boot Devices
- StorCLI RAID5 Online Expansion: Source Lab Setup, Migration and Capacity Checks
- StorCLI Reference for Legacy MegaRAID: Virtual Drives, Rebuilds, Cache and Foreign Configuration
- ARCCONF Reference for Legacy PMC/Adaptec Controllers: Queries, Arrays and State Changes
UEFI Mode
- 9230 SATA M.2 RAID in UEFI: Status, Deletion, RAID 1 Creation and Rebuild
- Configure a MegaRAID 9560 Controller in UEFI on a Two-Socket Server
- PM8060 UEFI RAID: Arrays, Dedicated/Global Spares, JBOD and Drive Location
- Configure 3108, 9361 and 9460 RAID Controllers in UEFI Mode on Eight-Socket Servers
- Configure LSI MegaRAID Controllers in Four-Socket UEFI Systems
- Configure MegaRAID 3108/9361/9460 Controllers in Two-Socket UEFI Systems
- Configure PM8204-Family RAID in Four-Socket UEFI Systems
- Configure PM8204-Family RAID in Two-Socket UEFI Systems
- Configure PM8222 RAID in the UEFI Firmware Utility
- SAS3008 IR RAID in UEFI: RAID0/1/1E/10, Global Spares and Rebuild Status
- Onboard Intel VROC SATA/sSATA RAID in UEFI: Arrays, Spares and Rebuilds
Drive Testing & Diagnostics
- Fujitsu RX2540 M4 SSD “Estimated Lifetime Below 60 Days”: Historical Investigation
- Synology DSM: An Increase in Drive Bad-Sector Count
- SMART Attributes: Values, Thresholds and Historical Vendor-Specific Meanings
- SMART Reallocated, Pending, Uncorrectable and CRC Counters
- NVMe list Usage: Zero or Partial Utilization Does Not Mean Lost Capacity
- fio Disk Testing: Archived NF5280M5 SSD Example
RAID Card User Guides
RAID Card Settings & Issues
- Replacing a Failed Single-Drive RAID 0: Source StorCLI Case
- 2288H V5: Repeated RAID BBU Present / Absent Events
- RAID Virtual-Disk Recreation: Changed SCSI ID Prevents Legacy Linux Boot
- Inspur SAS3008 Add-In Cards: Two Part-Number Families
- NF8480M5 / PM8204: RAID5 Device Offlined After a Disk Failure
- M5 Onboard Intel RAID and SAS Cards: Archived Disk-Ordering Workaround
- Legacy RAID BIOS Utilities: Select the Boot Virtual Drive
- LSI 9271-8i: Enable JBOD in the Source Firmware Environment
- LSI 9361: Alarm Continues After Rebuild with Emergency-Spare State