LSI 9361: Alarm Continues After Rebuild with Emergency-Spare State

Problem

The source describes an LSI 9361 controller that continued beeping after rebuild, with a drive showing emergency spare: yes or commissioned spare: yes. If the condition is unclear, collect controller logs and contact the vendor support channel given in the source: lckf@ieisystem.com.

Case cause and scope

The vendor describes a RAID 1 member being moved to another host and rebuilt with an empty drive. Afterward, the drive retained both member and emergency-spare attributes. The article lists LSI 9361 cards, but this cause must be confirmed from the actual controller/drive state; a continuing alarm can also require other diagnosis.

Source resolution

Confirm backups, drive identities and array health before following a procedure that removes a member or triggers a rebuild. These steps apply to the described spare-state case, not every rebuild alarm.

  1. Open Ctrl Mgmt. Clear Maintain PD Fail History and apply the change.
Original English controller settings with Maintain PD Fail History checked before the change

Before: Maintain PD Fail History is checked.

Original English controller settings with Maintain PD Fail History unchecked after the change

After: Maintain PD Fail History is unchecked; the other pictured settings are retained.

  1. Set Emergency Spare to GHS (Global Hot Spare) and save.
  2. For the confirmed affected drive, the source instructs removing/reinserting it and allowing rebuild. If several drives show the condition, process only one at a time and wait for its rebuild to finish successfully before touching the next. Do not remove another member if redundancy has not been restored.

Broadcom documents Emergency Spare as a controller policy with None, UG, GHS and UG/GHS choices. Here GHS is the source’s policy selection, not an instruction to arbitrarily convert a data member into a new hot spare. The two source images illustrate the history checkbox; they do not show the Emergency Spare selector.