SAS3008 IR RAID in UEFI: RAID0/1/1E/10, Global Spares and Rebuild Status

These archived examples use a server BIOS UEFI configuration interface. The original screenshots are already in English and remain unchanged. Confirm the actual controller, drive mapping, firmware, boot mode and supported OS driver. Changing boot/storage modes or entering setup through a restart can interrupt an installed system.

Creation and deletion can destroy existing data; identify the intended available drives and protect required data first. The article contains separate examples, rather than one uninterrupted sequence in which all arrays coexist. A controller’s successful-operation or Normal/Optimal state alone does not verify completed initialization, filesystem access, OS boot or backups.

The source uses LSI SAS3 MPT Controller Version 18.00.00.00 on SAS3008. This is an IR-firmware workflow; the presence of a SAS3008 chip alone does not mean an IT-mode HBA exposes the same RAID menus. The shown disk IDs use the controller’s own enclosure/slot mapping.

1. Set the appropriate UEFI policies

Under Advanced → CSM Configuration, the source keeps CSM Support Enabled, sets Boot Mode to UEFI Mode, and sets Network, Storage, Video OPROM Policy and Other PCI devices to UEFI. Confirm these are appropriate for the actual installation:

Original English CSM navigation and UEFI boot/option-ROM policies (source figure 1)
Original English CSM navigation and UEFI boot/option-ROM policies (source figure 2)

2. View a virtual disk

Under Advanced, select LSI SAS3 MPT Controller SAS3008, then LSI SAS3 MPT Controller Version 18.00.00.00. Open Virtual Disk Management → Manage Virtual Disk Properties and select the intended VD:

Original English SAS3008 navigation and virtual-disk properties (source figure 3)
Original English SAS3008 navigation and virtual-disk properties (source figure 4)
Original English SAS3008 navigation and virtual-disk properties (source figure 5)
Original English SAS3008 navigation and virtual-disk properties (source figure 6)
Original English SAS3008 navigation and virtual-disk properties (source figure 7)

The property example lists Volume 605, RAID0, 14903 GB, Optimal and Write-Cache Enabled. Other sections reuse volume IDs with different levels, so identify the real configuration rather than assuming every Volume 605 picture is the same array.

3. Delete a virtual disk

Open the controller and Virtual Disk Management. For deletion the actual menu is Select Virtual Disk Operations, rather than the source prose’s Select Virtual Disk Properties. Choose the intended VD; the dropdown includes volumes 604 and 605:

Original English virtual-disk operation path and target dropdown (source figure 8)
Original English virtual-disk operation path and target dropdown (source figure 9)
Original English virtual-disk operation path and target dropdown (source figure 10)
Original English virtual-disk operation path and target dropdown (source figure 11)
Original English virtual-disk operation path and target dropdown (source figure 12)

Choose Delete Virtual Disk. The source’s selected target is Volume 604, with Background Init in progress at 0% shown on the underlying page. The delete warning says the operation causes data loss. Set Confirm to Enabled and choose Yes only when deletion is intended and required data is protected. The last source message reports Operation completed successfully:

Original English delete action, data-loss confirmation and completion message (source figure 13)
Original English delete action, data-loss confirmation and completion message (source figure 14)
Original English delete action, data-loss confirmation and completion message (source figure 15)
Original English delete action, data-loss confirmation and completion message (source figure 16)

4. Create RAID0

Open SAS3008 → LSI SAS3 MPT Controller → Controller Management → Create Configuration:

Original English controller Create Configuration navigation (source figure 17)
Original English controller Create Configuration navigation (source figure 18)
Original English controller Create Configuration navigation (source figure 19)
Original English controller Create Configuration navigation (source figure 20)

Select RAID0 and open Select Physical Disks. The firmware’s help text lists RAID0 2–10 disks, RAID1 two disks, RAID1E 3–9 disks and RAID10 4–10 disks. These are this interface’s stated limits, not a guarantee that every tool or firmware reports the same limits. The same help text warns that selected-drive data will be deleted:

Original English RAID-level menu and physical-disk selection action (source figure 21)
Original English RAID-level menu and physical-disk selection action (source figure 22)

Enable only the intended members. This example chooses SATA HDDs 0:2:0 and 0:2:1, each shown as 7452 GB, leaving the other listed drives Disabled. Apply Changes:

Original English RAID0 member enablement and Apply Changes (source figure 23)
Original English RAID0 member enablement and Apply Changes (source figure 24)

Set Confirm to Enabled, review the target and choose Yes. The source shows Operation completed successfully, then a property view with RAID0 Optimal. A separate initialization/OS access test is not shown:

Original English RAID0 confirmation, completion and Optimal property view (source figure 25)
Original English RAID0 confirmation, completion and Optimal property view (source figure 26)
Original English RAID0 confirmation, completion and Optimal property view (source figure 27)
Original English RAID0 confirmation, completion and Optimal property view (source figure 28)

5. Create RAID1

Repeat SAS3008 → LSI SAS3 MPT Controller → Controller Management → Create Configuration, then select RAID1 and Select Physical Disks:

Original English RAID1 creation navigation and level selection (source figure 29)
Original English RAID1 creation navigation and level selection (source figure 30)
Original English RAID1 creation navigation and level selection (source figure 31)
Original English RAID1 creation navigation and level selection (source figure 32)
Original English RAID1 creation navigation and level selection (source figure 33)
Original English RAID1 creation navigation and level selection (source figure 34)

This separate example enables drives 0:2:2 and 0:2:3, each 7452 GB. Leave unrelated disks Disabled and choose Apply Changes. Set Confirm to Enabled and choose Yes only for the intended creation. The final message reports successful completion:

Original English RAID1 two-member selection, confirmation and completion (source figure 35)
Original English RAID1 two-member selection, confirmation and completion (source figure 36)
Original English RAID1 two-member selection, confirmation and completion (source figure 37)
Original English RAID1 two-member selection, confirmation and completion (source figure 38)
Original English RAID1 two-member selection, confirmation and completion (source figure 39)

6. Create RAID1E

Use the same controller/Create Configuration path. The open level menu still shows an intermediate RAID10 field, but the next form explicitly shows RAID1E. Select the final intended level and physical disks:

Original English RAID1E navigation and level-selection screens (source figure 40)
Original English RAID1E navigation and level-selection screens (source figure 41)
Original English RAID1E navigation and level-selection screens (source figure 42)
Original English RAID1E navigation and level-selection screens (source figure 43)
Original English RAID1E navigation and level-selection screens (source figure 44)
Original English RAID1E navigation and level-selection screens (source figure 45)

The source enables three SATA HDDs, 0:2:0 through 0:2:2, and leaves the remaining disks Disabled. This is another separate configuration example, not simultaneous reuse of members from the earlier arrays. Apply Changes, set Confirm to Enabled and choose Yes when correct. The source then reports Operation completed successfully:

Original English three-member RAID1E configuration and completion (source figure 46)
Original English three-member RAID1E configuration and completion (source figure 47)
Original English three-member RAID1E configuration and completion (source figure 48)
Original English three-member RAID1E configuration and completion (source figure 49)

7. Create RAID10

Open the controller, Controller Management and Create Configuration again. Select RAID10 in the level menu, then Select Physical Disks:

Original English RAID10 creation navigation and selected menu option (source figure 50)
Original English RAID10 creation navigation and selected menu option (source figure 51)
Original English RAID10 creation navigation and selected menu option (source figure 52)
Original English RAID10 creation navigation and selected menu option (source figure 53)
Original English RAID10 creation navigation and selected menu option (source figure 54)

The final selection form shows RAID10 with four members enabled, 0:2:0 through 0:2:3, and the rest Disabled. Apply Changes, enable Confirm and choose Yes only for the intended configuration. The last message reports successful completion:

Original English four-member RAID10 selection and completion message (source figure 55)
Original English four-member RAID10 selection and completion message (source figure 56)
Original English four-member RAID10 selection and completion message (source figure 57)
Original English four-member RAID10 selection and completion message (source figure 58)

8. Assign a global hot spare

Open the controller → Virtual Disk Management → Manage Virtual Disk Properties and select the intended VD:

Original English hot-spare navigation and virtual-disk selection (source figure 59)
Original English hot-spare navigation and virtual-disk selection (source figure 60)
Original English hot-spare navigation and virtual-disk selection (source figure 61)
Original English hot-spare navigation and virtual-disk selection (source figure 62)
Original English hot-spare navigation and virtual-disk selection (source figure 63)

The target dropdown picture shows Volume 605 RAID10, 14903 GB, Optimal. The following Manage Global Hotspare Disks picture switches to Volume 604 RAID1, 7451 GB, Optimal and Write-Cache Disabled. Keep those two views distinct. Open Manage Global Hotspare Disks on the verified configuration:

Original English global-spare action on the separate Volume 604 RAID1 example

Choose a compatible available disk and set it Enabled. The source candidate is 0:2:5, SATA HDD-512e, 7452 GB; 0:2:6 and 0:2:7 remain Disabled. Select Assign Global Hotspare Disk. The source reports successful operation. This is a global spare assignment rather than a promise of a dedicated spare for one selected VD:

Original English spare candidate, Assign Global Hotspare Disk and completion message (source figure 65)
Original English spare candidate, Assign Global Hotspare Disk and completion message (source figure 66)
Original English spare candidate, Assign Global Hotspare Disk and completion message (source figure 67)

9. Check a degraded array and rebuilding disk

Open the controller → Virtual Disk Management → Manage Virtual Disk Properties. The first property picture here is Volume 605 RAID0 Optimal; the next switches to the separate Volume 604 RAID1 case and shows Degraded, 7451 GB, Write-Cache Disabled:

Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 68)
Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 69)
Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 70)
Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 71)
Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 72)
Original English recovery navigation and separate Optimal RAID0/Degraded RAID1 views (source figure 73)

Follow the server’s supported replacement process for the verified failed member. To inspect a replacement, open Physical Disk Management → View Physical Disk Properties and select the actual device. The dropdown screenshot initially shows 0:2:0 Ready, while the final detail page is Physical Disk ID 0:2:2, State Rebuilding. Do not assume the intermediate default choice identifies the final rebuild destination:

Original English physical-disk navigation, selector and actual Rebuilding detail page (source figure 74)
Original English physical-disk navigation, selector and actual Rebuilding detail page (source figure 75)
Original English physical-disk navigation, selector and actual Rebuilding detail page (source figure 76)
Original English physical-disk navigation, selector and actual Rebuilding detail page (source figure 77)

The final rebuilding disk is a 7452 GB SATA ST8000NM0055-series device. The source says a completed rebuild returns to Optimal, but supplies no later completed-state capture in this branch. Rebuilding is still in progress; verify completion and the resulting redundant-array and data-access state afterward. A failed RAID0 member does not gain recoverability from this RAID1 rebuild example.

Broadcom’s English SAS3IRCU guide is a related command-line reference for SAS3008 Integrated RAID and compatible member/spare constraints. It is not an identical UEFI screenshot guide; where its CLI limits differ, follow the installed controller’s supported firmware documentation and actual interface.

References