9230 SATA M.2 RAID in Legacy BIOS: Ctrl+M Configuration and Rebuild Status

This is an archived Inspur OEM example for a Marvell 9230-based SATA M.2 RAID controller. Match the actual firmware, server boot mode and supported replacement drive; a generic 88SE9230 chip specification does not prove every feature is exposed by this OEM firmware. The source’s screenshots are already in English. Viewing, deleting, creating and rebuilding are separate operations; deleting/recreating a working array is not a routine repair for a failed mirror member.

1. RAID configuration

1.1 View the existing array

The source enters BIOS → Advanced → CSM Configuration:

Original English BIOS Advanced page with CSM Configuration highlighted

For its legacy option-ROM workflow, the pictured Boot option filter is Legacy only and the boxed Network/Storage/Video/Other PCI device entries are Legacy. This describes that example; do not blindly change every boot/option-ROM policy on an installed system. Confirm compatibility with the OS boot layout and the required service procedure:

Original English CSM page with Legacy only and four Legacy option-ROM policies boxed

During POST, find the Marvell 88SE92xx adapter message and use Ctrl+M to enter the controller setup. The source POST screen identifies BIOS 1.0.0.1031 and a Functional RAID 1 volume with two configured Intel SSDs:

Original English MarvellPOSTscreen with FunctionalRAID1andCtrl+Mprompt

In Marvell BIOS Setup, use the arrow keys to select the intended virtual disk and inspect its RAID mode, members and status. The detail capture shows New_VD, RAID 1, 223.5GB, 64K stripe and BGA not running:

Original English virtual-disk information showing RAID1,223.5GBandFunctionalstatus

1.2 Delete an array only when its data may be discarded

The source selects the virtual disk, presses Enter and chooses Delete:

Original English Delete action on the selected virtual disk

It confirms both Delete Virtual Disk and Delete MBR prompts with the keyboard Y/Yes action. The second prompt concerns the disk’s master boot record; these confirmations are destructive, not informational. Confirm the real target and retained backup before accepting them:

Original English confirmation for deleting the selected virtual disk
Original English separate Delete MBR confirmation

1.3 Create the source RAID 1 example

For two intended available members, select HBA 0: Marvell 0, press Enter and choose Configuration Wizard. The shown controller information identifies device 9230, revision A1, firmware 2.3.24.1008 and Supported Mode RAID 1; the broader chip’s feature list is not an instruction to select an unavailable mode:

Original English controller Configuration Wizard menu with Supported ModeRAID1

Use Space to select the two verified free physical drives, then Enter to continue. The source selection shows two 223.5GB-class SATA SSDs, not two disk identifiers to reuse on another server:

Original English two-member selection with SpaceSelectinstruction

Review the RAID level, capacity, stripe size, initialization choice and name. The source illustrates RAID 1, 223.5GB, 64K, Quick init Yes and Name Default; these are pictured values, not universally correct defaults:

Original English Create Virtual Disk settings before confirmation

Choose Next and confirm the creation prompt with the source’s Y/Yes action only when the selected members and intended erasure are correct. The next capture shows New_VD and its two members in the topology:

Original English Create Virtual Disk confirmation
Original English postcreation topology with New_VDandtwoSSDmembers

1.4 Passthrough/JBOD

The source says unconfigured drives default to passthrough when RAID 1 is not used. It supplies no separate JBOD-setting screenshot or migration procedure. Verify the actual firmware’s behavior and OS device presentation; do not delete an existing mirror simply to test passthrough.

2. A single member goes offline

The source describes a RAID 1 mirror becoming Degraded while the surviving member continues serving reads/writes, then automatically rebuilding after a supported replacement is fitted. This assumes a usable surviving member and compatible replacement; it does not guarantee access after an additional fault or prove that replacement is hot-swappable. Follow the exact powered-down/hot-swap service instructions for the M.2 assembly.

POST can display Rebuilding. Enter Ctrl+M and select the virtual disk to inspect progress. The final detail screen shows BGA running and a 24% rebuild; it is not a completed/healthy mirror confirmation:

Original English POSTmessage showing RAID1Rebuilding
Original English RAID1rebuild details showing BGArunningand24percent

No controller configuration, deletion, installation or replacement was performed during this translation. Verify the real volume, completed rebuild, OS boot and required data access before returning a system to service.

References

Can't find an answer?

Upload a log for AI diagnosis, or ask the AI assistant directly in the console.