FAS25xx: e0a, e0b, e0M and e0P Ports Down
Source scope and symptom
The source lists FAS2520, FAS2552 and FAS2554. Node-management networking is unreachable and the port link LEDs are off. In the recorded case, e0M being down prevents collection of the expected AutoSupport evidence through that path; use available console/SP/support data rather than assuming every AutoSupport route is impossible.
Source sysconfig example
sysconfig -a
Node: NetApp-2
NetApp Release 8.3P2: Tue May 19 01:39:13 PDT 2015
System ID: XXXXXXXXX (NetApp-2); partner ID: XXXXXXXXX (NetApp-1)
System Serial Number: XXXXXXXXXXXX (NetApp-2)
slot 0: Quad Gigabit Ethernet Controller 82580
e0a MAC Address: 00:xx:xx:xx:xx:48 (auto-1000t-fd-down)
e0b MAC Address: 00:xx:xx:xx:xx:49 (auto-1000t-fd-down)
e0M MAC Address: 00:xx:xx:xx:xx:4a (auto-1000t-fd-down)
e0P MAC Address: 00:xx:xx:xx:xx:4b (auto-1000t-fd-down)Source event example
event log show
7/17/2020 01:19:39 NetApp-2 INFORMATIONAL snmp.link.down: Interface 2 is down.
7/17/2020 01:19:39 NetApp-2 INFORMATIONAL netif.linkDown: Ethernet e0a: Link down, check cable.
7/17/2020 01:19:39 NetApp-2 INFORMATIONAL snmp.link.down: Interface 1 is down.
7/17/2020 01:19:38 NetApp-2 INFORMATIONAL netif.linkDown: Ethernet e0M: Link down, check cable.
7/17/2020 01:19:38 NetApp-2 INFORMATIONAL snmp.link.down: Interface 7 is down.
7/17/2020 01:19:38 NetApp-2 INFORMATIONAL netif.linkDown: Ethernet e0P: Link down, check cable.
7/17/2020 01:19:38 NetApp-2 INFORMATIONAL snmp.link.down: Interface 8 is down.
7/17/2020 01:14:09 NetApp-2 NOTICE rdb.ha.verified: Verified that cluster high availability (HA) is configured correctly, and that on-disk mailboxes are intact.All original timestamps and explicit PDT text are retained; these are archived examples, not the current system state.
Cause and service action
The source attributes the combined symptoms to CHW-219 and calls for controller replacement. The matching public English CHW-219 description confirms Intel82580-related missing/failed-port symptoms; full remediation details may require vendor sign-in. Confirm the actual hardware fault, replacement unit and HA/service procedure before replacement. A single disconnected or administratively down port alone does not establish this fault.
Related case: ports missing with Invalid PCIe device detected. See also the stored CHW-219 reference.