IBM DS Storage: Connect to Management Port and Collect Logs
IBM DS Storage Connection
- Log in to the storage system
- Connect two Ethernet cables to the idle management ports of both controllers

Controller A Port 1 IP: 192.168.128.101
Controller A Port 2 IP: 192.168.129.101
Controller B Port 1 IP: 192.168.128.102
Controller B Port 2 IP: 192.168.129.102
- Using Controller B Port 2 as an example, attempt to ping the management port IP address (typically requires about 2 minutes after connecting the cable for the ping to succeed)

- Open the IBM DS Storage Manager software on your laptop
- Click the Link button at the top-left corner of the software window, then select Manual in the pop-up window

- Enter the management port IP address 192.168.129.102, then click Add

- When the following prompt appears, click Yes

- When the following prompt appears, click No

- The previously added storage array will appear in the left window; double-click it

- When the following prompt appears, select Yes

- If the following prompt appears, select Cancel

- Check error messages and collect logs
- Click Storage Array Needs Attention to view errors

- Confirm there are no errors other than Volumes Not On Preferred Path, then click Close

- Click Collect Support Data Manually to collect logs

- In the pop-up window, select Browse, choose a destination directory, enter a file name, then click Start to begin log collection.

- Enter the save file name, for example E2700_SN007_20230113, then click Save

- After completion, click OK

Images localized into English for illustration; labels may vary by product version.