Install IPMItool and Use Common BMC Commands: Archived OEM Guide

Archived OEM installation and command reference for Windows, Linux and VMware ESXi. The source mixes IPMItool 1.8.18 downloads, 1.8.11 Linux build screenshots and a 1.8.15-1 ESXi VIB; these are separate legacy examples, not a current supported software bundle. Six English instructional images and nineteen original English figures are retained. Example Windows paths are simplified; the original credential-bearing help screenshot is replaced without sending its password to the image service. No tool, driver, VIB or BMC command was installed or executed while preparing this article.

I. Install and verify IPMItool

1. Windows: remote access from an administrator workstation

The source supplies this archived Windows package for out-of-band management. Obtain and verify an appropriate supported package for the actual OS and server; the source filename alone does not establish support or trust.

Original OEM attachment: IPMIToolWin1.8.18.zip

1) Extract the complete package to the intended directory. The English illustration uses C:\Tools\IPMIToolWin in place of the original personal/Chinese folder path and retains the imbdriver directory, ipmitool.exe and libeay32.dll.

Illustrated Windows IPMItool package directory

2) Open Command Prompt, then change to the directory containing ipmitool.exe. Use cd /d if changing drives. The illustrated cd command enters the example directory; it does not contact a BMC.

Command Prompt search result

Enter the example IPMItool directory

3) Check the executable’s help/version, then separately verify an authorized read-only BMC query if required. The original remote-command screenshot printed No command provided and help, so it did not demonstrate a successful remote connection. Its exposed authentication argument is omitted from the replacement illustration.

ipmitool.exe -h
ipmitool.exe -V

Credential-free instructional help output

Recreated help illustration using -h and a declared example path; no remote authentication or live output is demonstrated.

2. Windows: local in-band access on the server

Original OEM attachment: IPMIToolWin.zip

1) Review the package instructions and available local IPMI interface/driver before installing anything. The source distinguishes x64 and x86 directories by Windows architecture; that is not a guarantee that this archived driver supports a current OS.

Source x64 and x86 driver directories with x64 highlighted

2) The source installer example supplies a destination directory. Its output explicitly detects an existing MSIPMI driver and skips IMBDRV installation before printing Installation Successful; do not read that as proof that a new IMBDRV driver was installed.

install.cmd C:\IMBDRV\Test

Illustrated IMB installer output retaining the skip message

3) Local access uses an appropriate supported local interface rather than the remote -H/-I lanplus/-U authentication arguments. The next source figure is help output only; validate an actual permitted query separately.

Original English local executable help output

3. Linux build and local device access

Original OEM attachment: ipmitool-1.8.18.tar.gz.zip

1) Identify the actual archive and release. The download label is 1.8.18, while the tar command and build figures use 1.8.11; inspect the package instead of assuming the names match. A .tar.gz.zip wrapper requires the appropriate archive step before tar can read the inner tarball.

Source Linux archive listing with version 1.8.11

2) For the source’s 1.8.11 tarball example, extract it and enter its actual directory:

tar -xvzf ipmitool-1.8.11.tar.gz
cd ipmitool-1.8.11

Source command entering the extracted 1.8.11 directory

3) Run the release’s configuration step with the required build dependencies, and inspect its result. The source output lists lanplus: no. That build cannot provide the later -I lanplus examples; verify a build with the required cryptographic support when IPMI 2.0 LAN access is intended.

./configure

Source configure command

Source configure result with lanplus disabled

4) Build and, where intended and authorized, install according to that release’s instructions. Compilation and system installation are different operations.

make
make install

Source make command

Source make install command

5) Local OpenIPMI access also requires a supported kernel interface. The source loads the following modules; inspect the actual distribution/kernel requirements rather than loading an unrelated driver solely because its name appears here.

modprobe ipmi_msghandler
modprobe ipmi_devintf
modprobe ipmi_si

Source local IPMI module commands

6) The kernel driver directory shown next is a version-specific example for 3.10.0-693.el7.x86_64. A local console is not limited to typing one character at a time; use the available input method and the actual path. Do not reuse a kernel-version path on another system.

Original English kernel IPMI driver directory

7) Inspect the actual device node, illustrated as /dev/ipmi0. Its existence alone does not establish working permissions or communication.

ls /dev

Source /dev listing highlighting ipmi0

8) A read-only query can verify local access when supported and permitted. The source FRU output is an example from an NF5280M5 system, not information extracted from the current host.

ipmitool fru list

Original English NF5280M5 FRU example

4. VMware ESXi: archived community VIB example

Original OEM attachment: ipmitool_esxi.zip

1) The source uses esxi_ipmitool-1.8.15-1.vib. Confirm support for the exact ESXi release, package and host policy before considering this legacy method. The following commands document the source workflow; they are not a recommendation to install an unverified community package on a current host.

Source ESXi VIB filename

2) The source changes the host software acceptance policy to CommunitySupported. This changes the host’s package trust policy; it is not an obligatory step for every supported IPMI utility installation.

esxcli software acceptance set --level=CommunitySupported

Source host acceptance-level change

3) The source then installs that VIB from its actual datastore path and checks the installed package list. Replace the example path with the intended verified package location; do not treat a successful package task as proof of working BMC access.

esxcli software vib install -v /vmfs/volumes/datastore1/tools/esxi_ipmitool-1.8.15-1.vib
esxcli software vib list | grep ipmitool

Source VIB installation task result

Source installed VIB listing

4) The package example places its executable in /opt/ipmitool/bin. A symlink is optional and changes /bin; check for an existing command and the host’s persistence/support rules before creating one. This location is package-specific, not a universal path for every 64-bit OS.

ln -s /opt/ipmitool/bin/ipmitool /bin/ipmitool
ipmitool fru list

Source optional command symlink

Source FRU command through the command path

Alternatively, invoke the installed binary using its actual full path, or change to its directory and use ./ipmitool. The last output is another source FRU example.

cd /opt/ipmitool/bin
./ipmitool fru list

Source explicit executable path

Original English example FRU output

II. Common commands

The templates below use ASCII hyphens. Replace angle-bracket placeholders with actual values before use; brackets and alternatives are notation, not literal shell arguments. Remote examples use -a to request a password privately instead of embedding it in the command line. Local queries need the appropriate local interface and access permissions; remove the remote connection/authentication arguments rather than treating lanplus as a local driver.

The command tables describe both queries and changes. Power off/reset can interrupt the host; BMC reset interrupts management access; LAN changes can disconnect the session; clearing SEL deletes event records; user commands alter access. Choose only the intended operation for the correct system.

1. Host power and BMC reset

OperationCommand template
Read power statusipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a power status
Power onipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a power on
Immediate power offipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a power off
Reset host poweripmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a power reset
Warm BMC resetipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a mc reset warm
Cold BMC resetipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a mc reset cold

2. LAN configuration

The source’s dual-socket M3 examples map channel 8 to dedicated and 1 to shared; its M4/M5 examples reverse that mapping. Confirm the actual channel on the actual firmware. The channel is required for lan set; do not assume it is optional everywhere. The source’s static-address sequence concerns manual configuration; DHCP is a separate alternative.

OperationCommand template
Read LAN settingsipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan print <CHANNEL>
Select static addressingipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan set <CHANNEL> ipsrc static
Select DHCP insteadipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan set <CHANNEL> ipsrc dhcp
Set static IPipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan set <CHANNEL> ipaddr <IP_ADDRESS>
Set subnet maskipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan set <CHANNEL> netmask <NETMASK>
Set default gatewayipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a lan set <CHANNEL> defgw ipaddr <GATEWAY>

3. Inventory, events and sensors

OperationCommand template
Read FRU inventoryipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a fru list
Read SELipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a sel list
Clear SEL recordsipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a sel clear
Read SDRipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a sdr
Read sensor listipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a sensor list

Retain any required event evidence before a deliberate SEL clear. Do not publish credentials or SNMP community strings when sharing diagnostic output.

4. BMC users

The source describes user ID 1 as anonymous and ID 2 as ADMIN for its example platforms; actual existing accounts vary. List and identify the intended user slot before any change. Naming a slot alone does not complete all access configuration. Privilege values shown in the source are 2 User, 3 Operator and 4 Administrator; channel-specific permissions still apply.

OperationCommand template
Read user listipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user list <CHANNEL>
Set a user slot nameipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user set name <USER_ID> <USER_NAME>
Set a password explicitlyipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user set password <USER_ID> <NEW_PASSWORD>
Set channel privilegeipmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user priv <USER_ID> <PRIVILEGE_LEVEL> <CHANNEL>
Enable a useripmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user enable <USER_ID>
Disable a useripmitool -H <BMC_ADDRESS> -I lanplus -U <BMC_USER> -a user disable <USER_ID>

NEW_PASSWORD is a placeholder, not a supplied secret. Consult the exact binary’s supported password-setting method and keep real values out of saved examples/history. Do not omit the new-password argument on the assumption that every build prompts; versions may clear the password instead. The source shorthand user enable/disable means two separate alternatives, as expanded above.

English primary references and source scope

IPMItool upstream project

IPMItool upstream command manual

No corresponding complete English edition of the OEM article or equivalent screenshot set was verified. The upstream English documentation was used to check command meaning and separate local drivers, remote interfaces and help output. Match its details to the installed release; this archived article’s older binaries can differ.

Can't find an answer?