Handling Foreign State Drives in MSM

I. Steps for Handling Foreign Status on a Newly Replaced Hard Drive

When the new hard drive status is (Foreign) Unconfigured Good, clear the Foreign Configuration of the hard drive. Then set the hard drive as a hot spare.

Handling Foreign State Hard Drives in MSM
  1. Clear Foreign Configuration:

Right-click the RAID controller, select Scan Foreign Configuration to scan for Foreign configurations.

Handling Foreign State Hard Drives in MSM

A prompt appears: 1 Foreign Drives were detected…

Then select Clear: remove logical configuration from all foreign drives, and click OK.

In the next prompt, check Confirm to confirm, click Yes to delete the foreign configuration.

Handling Foreign State Hard Drives in MSM

The hard drive will change to Unconfigured Good status.

  1. Set as Spare or Replace Missing Hard Drive:

Choose one of the following two scenarios:

RAID Group has no Missing Hard Drives: Right-click the hard drive, then select Assign Global Hot Spare to set the hard drive as a global hot spare.

RAID Group has Missing Hard Drives: Right-click the hard drive, then select Replace Missing Drive to replace the missing drive with the hard drive.

Handling Foreign State Hard Drives in MSM

Right-click the RAID group, select Show Progress to view the current RAID group rebuild progress.

Handling Foreign State Hard Drives in MSM

II. Accidentally unplugged and reinserted hard drive, causing it to be used as a new hard drive.

MegaRAID Storage Manager shows Slot 6 hard drive as Foreign Unconfigured Bad.

Note: Generally, Unconfigured Bad indicates a failed drive. However, if this status was caused by accidental unplugging, the hard drive can still be used as a new drive.

Handling Foreign State Hard Drives in MSM

If only one hard drive in the RAID group was accidentally unplugged and reinserted and the RAID group status is Degraded, follow the menu below to set the hard drive to Good, then proceed with Part I of this document to clear Foreign information and replace the Missing hard drive.

Handling Foreign State Hard Drives in MSM
10 views Updated 2026-11-07

More in this groupRAID Card Settings & Issues

View all 16 in this group