Rebuilding After Disk Drop on an LSI RAID Controller in WebBIOS

Description

This document primarily introduces the detailed operation process for manually rebuilding after a disk drop in an LSI 8708EM2 SAS RAID array, where multiple insertions and removals of the disk prevent automatic Rebuild.

1. Press <ctl>+<H> to enter the LSI 8708EM2 SAS RAID controller. You will see Slot 1 disk as shown in the figure below.

Missing.

Note: If the state displayed under the LSI 8708EM2 SAS RAID controller is not as shown below, please hot-swap the offline hard drive under the controller.

and scan devices via Scan Devices to make it appear in the state shown below.

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

2. Select Physical view and press <Enter> to enter the disk physical status query;

Phone: 025-68891010

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

3. Move the cursor to FOREIN SLOT:1,SATA,HDD,930.390GB,Unconfigured Bad, i.e., the offline hard drive, and press <Enter>

to enter the MegaRAID BIOS Config Utility Drive interface; the current offline physical drive state

is Unconfigured Bad. Select make unconf good and click GO;

Phone: 025-68891010

4. The Physical Drive State changes to Unconfigured Good. Select Replace Missing PD and click Go;

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

5. The Physical Drive State changes to Offline. Select Rebuild Drive and click Go;

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

Phone: 025-68891010

6. The interface displays Rebuild Progress;
Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

7. Click PD Progress Info to view the Rebuild execution progress percentage;

Phone: 025-68891010

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

8. Return to the RAID controller home main interface to check that the disk status has changed to Rebuild;

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

Phone: 025-68891010

9. On the main interface, click PD Progress Info to re-enter the Rebuild disk and view the Rebuild execution progress percentage;

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

10. Status after Rebuild completion;

Phone: 025-68891010

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

11. Return to the controller home main interface to check that the RAID status has changed from the dropped disk state Degraded to Optimal,

and simultaneously the RAID card stops alarming;

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

Before Rebuild completes, the RAID controller remains in an alarm state until the rebuild is complete.

Phone: 025-68891010

The execution time is proportional to the disk capacity and server performance. You can click the small speaker icon on the menu to turn off the alarm.

Rebuilding After Disk Drop on LSI Array Card Under WebBIOS

 No system data loss will occur during the Rebuild process.