Importing Foreign Configuration After Replacing RAID Controller (MSM)

Importing Foreign Configuration after Raid Adapter has been replaced

Environment

  1. IBM X Series Servers
  2. IBM ServeRAID-MR10K SAS/SATA Controller

Cause

After Replacing the Raid Adapter on IBM X Series, Server may report Foreign Configuration message

Resolution

1) Power on the Server
Import Foreign Configuration after Replacing RAID Adapter (MSM)
,
2) During Post Message will be displayed about Foreign Configuration. Press any key or {C} to load the configuration Utility.
3) Additional Warning message is displayed, Press {Y} to confirm
In this case Server just has one Raid Adapter installed, ie- IBM ServerRAID-MR10K, If multiple Raid adapters are installed the same will be listed, as below. Click Start to Continue.
Import Foreign Configuration after Replacing RAID Adapter (MSM)

4) In this case the Adapter has found a single Foreign Configuration, DO NOT CLEAR THE CONFIGURATION.
Click on Preview to View the configuration
Import Foreign Configuration after Replacing RAID Adapter (MSM)

Here we have we have 4 SAS Hard Drives and 1 Virtual Disk –VD0- Raid Level 0 Configured
Import Foreign Configuration after Replacing RAID Adapter (MSM)

5) Select Import to save the configuration.
Import Foreign Configuration after Replacing RAID Adapter (MSM)

6) Configuration has been imported, Return to Main Web Bios Menu Options.
Import Foreign Configuration after Replacing RAID Adapter (MSM)
7 views Updated 2026-11-07

More in this groupRAID Card Settings & Issues

View all 16 in this group