ZTE Server BMC Log File Usage Quick Reference
API data interaction log
http.log
Fault diagnosis log
faultdiagnose.log
System Event Log
SEL.dat
BIOS black box self-test log
BIOS_LOG
Serial port output log
HostSerialPort.log
Critical system event log
crit.log
alarm.log
Host information record log
hostinfo.log
===
# General hardware errors / alertsconf/zte/ALARM.db
conf/redis-dump.rdb
extlog/BMC1/SEL.dat
conf/BMC1/ast2500evb_ami/SDR.dat
conf/BMC1/ast2500evb_ami/DevTable.dat
mnt/nandflash1/log/partfault.log
mnt/nandflash1/log/system.log
# Memory / DIMMmnt/nandflash1/log/faultdiagnose.log
mnt/nandflash1/log/faultdiagnose.log.1
mnt/nandflash1/BlackBox/BIOS_LOG
mnt/nandflash1/log/hostinfo.log
mnt/nandflash1/Asset/dimm.info
conf/sdm/memory_change_record.json
mnt/nandflash1/log/ecc_error_check.log
mnt/nandflash1/hostcheck/msr
# Disk / SMARTmnt/nandflash1/log/pdsmartdata
conf/zte/latestpdsmartdata
mnt/nandflash1/log/http.log
mnt/nandflash1/log/http.log.1
#RAID card / Logical drive / RAID card battery
mnt/nandflash1/log/obstorage.log
mnt/nandflash1/log/obstorage.log.1
conf/compbook/003_*.dat
conf/compbook/009_*.dat
var/log/stevent.log
var/log/stevent.log.1
var/log/storage.log
var/log/storage.log.1
Note: The RAID card battery (BBU / Energy Pack) has no independent file; extract it from obstorage.log and compbook/*.dat. http.log and compbook cover both hard drives and RAID controllers, classify as needed.