MegaCLI Common Command Quick Reference
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL [Check RAID level]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL [Check RAID controller information]
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL View [Hard disk information]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll [Check battery information]
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL [Check RAID controller logs]
/opt/MegaRAID/MegaCli/MegaCli64 -adpCount [Display adapter count]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL [Display adapter time]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aAll [Display all adapter information]
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LALL -aAll [Display all logical drive group information]
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll [Display all physical information]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL |grep 'Charger Status' [Check charging status]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL[Display BBU status information]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL[Display BBU capacity information]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL [Display BBU design parameters]
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL [Display current BBU properties]
/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL [Display RAID controller model, RAID settings, and Disk-related information]
Check
/opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALLww
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -CfgDsply -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -EncInfo -aALL
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL
MegaCli Commands:Reference link (maths.cam.ac.uk)
Reference link (maths.cam.ac.uk)
Replace
MegaCli -PDList -a0
MegaCli -PDOffline -PhysDrv[252:3] -a0
MegaCli -PDMarkMissing -PhysDrv [252:3] -a0
MegaCli -PDPrpRmv -PhysDrv [252:3] -a0
MegaCli -PDHSP -Set -PhysDrv[252:3] -a0
MegaCli -PDRbld -ShowProg -PhysDrv[252:3] -a0In case you’re not working with hot spares, you must re-add the new drive to your RAID virtual drive and start the rebuilding
MegaCli -PdReplaceMissing -PhysDrv[252:3] -Array0 -row0 -a0
MegaCli -PDRbld -Start -PhysDrv[252:3] -a0
MegaCli -PDRbld -ShowProg -PhysDrv[252:3] -a0How to Rebuild a Drive That is Marked as "Foreign" When Inserted:
MegaCli -PDMakeGood -PhysDrv[252:5] -a0
MegaCli -CfgForeign -Clear -aALL
MegaCli -PDHSP -Set -PhysDrv[252:6] -a0/opt/MegaRAID/MegaCli/MegaCli -PDMakeGood -PhysDrv[64:2] -force -a0
/opt/MegaRAID/MegaCli/MegaCli -PDHSP -Set -PhysDrv[64:2] -a0
/opt/MegaRAID/MegaCli/MegaCli -PDRbld -ShowProg -PhysDrv[64:0] -a0