Sangfor AD Load Balancer Inspection Manual

Device Hardware Status Check

POWER Indicator Status Check

Inspection Requirements

When the device is operating normally, the POWER indicator light remains on.

Inspection Method

Log in to the device remotely and check the POWER status information on the device control panel.

Inspection Results

Sangfor AD Load Balancing Device Inspection Manual

Rectification Suggestions

If the POWER indicator status is abnormal, verify whether there is a power supply anomaly or if the power module has failed.

Device Fan Operation Status Check

Inspection Requirements

The device fans must be in normal operation, and no abnormal fan noise should occur during device operation.

Inspection Method

Log in to the device remotely and check the device fan status information.

Inspection Results

Sangfor AD Load Balancing Device Inspection Manual

Rectification Suggestions

If there is an abnormal sound inside the device, it may be caused by abnormal operation of the fans [or hard drives]. Immediately disconnect the power supply to stop the device. If a standby machine is available, immediately switch the system to the standby machine.

Device CPU Usage Check

Inspection Requirements

The device CPU usage rate must not exceed 80%.

Inspection Method

Access the device status interface via the device console [Network-wide Monitoring/Home Page] to check if CPU utilization remains high for an extended period.

Inspection Results

Sangfor AD Load Balancing Device Inspection Manual

Rectification Suggestions

If CPU utilization remains high for an extended period, perform the following steps:

1. View the interface throughput column in [Network-wide Monitoring/Home Page/Traffic Analysis] to check if the current bandwidth is consistently saturated.

2. View the business traffic ranking column in [Network-wide Monitoring/Home Page/Traffic Analysis] to check if any users are generating unusually high traffic spikes.

3. Enable the device's internal network DoS attack prevention module ([Terminal Behavior Security/Internet Access Security/Safety Capabilities/Safety Configuration]) to check if the device has been subjected to a DoS attack. DoS attack prevention logs can be viewed in [System Management/System Diagnostics/System Logs].

Device Memory Usage Check

Inspection Requirements

The device memory usage rate must not exceed 80%.

Inspection Method

Access the device status interface via the device console [Network-wide Monitoring/Home Page] to check if memory utilization remains high for an extended period.

Inspection Results

Sangfor AD Load Balancing Device Inspection Manual

Rectification Suggestions

If memory utilization remains high for an extended period, perform the following steps:

1. Check the interface throughput column in [Global Monitoring / Home Page / Traffic Analysis] to verify if the current bandwidth is consistently saturated.

2. Check the business traffic ranking column in [Global Monitoring / Home Page / Traffic Analysis] to identify if there are users with unusually high burst traffic.

3. Enable the device's internal network DoS attack prevention module ([Terminal Behavior Security / Terminal Internet Security / Security Capabilities / Security Configuration]). Check if the device has been subjected to DoS attacks. DoS attack prevention logs can be viewed in [System Management / System Diagnostics / System Logs].

Device Throughput Check

Inspection Requirements

The device's traffic throughput value must remain stable during operation, without significant traffic bursts.

Inspection Method

Access the device status interface via the device console [Global Monitoring / Home Page] to inspect the traffic analysis situation. Traffic analysis allows for the examination of global internet traffic, including the interface throughput line chart (real-time traffic on all WAN ports), user traffic ranking, application traffic ranking, and business traffic ranking.

Interface Throughput Line Chart: The device dynamically displays real-time data transmission and reception status for external interfaces using a line chart. It also shows the forwarding status of the interface over a specific time period.

Inspection Results

Sangfor AD Load Balancer Device Inspection Manual

Rectification Recommendations

If the device throughput exhibits significant bursts, check for abnormal network fluctuations or attacks.

Rule Base Version Check

Inspection Requirements

The rule base upgrade service validity period must not be 'Expired', and the current rule base version must be up to date.

Inspection Method

Access the device console [System Management / System Configuration / System Update / Rule Base Upgrade] interface to check the device's rule base upgrade details.

Inspection Results

Sangfor AD Load Balancer Device Inspection Manual

Rectification Recommendations

1. If the upgrade service validity period is 'Expired', promptly purchase the corresponding authorization file.

2. When connected to the network, the device will automatically update to the latest rule base; when offline, select the option to import the latest version locally. Please update the rule base version promptly to fix vulnerabilities and defend against new intrusions and attacks.

Dual-Node Hot Standby Status Check

Inspection Requirements

The device dual-node hot standby status must align with actual business requirements.

Inspection Results

Sangfor AD Load Balancer Device Inspection Manual

Inspection Method

Access the device console [System Management / Network Configuration / High Availability] interface to check the device's dual-node hot standby enabled status.

Rectification Recommendations

If the dual-node hot standby service status is abnormal, check whether the configurations at both ends are correct and whether there are faults in the intermediate heartbeat link.

High-Risk Log Content Check

Inspection Requirements

The device system logs must not contain a large number of error logs and alert logs.

Inspection Method

Access the device console [System Management / System Diagnostics / System Logs] interface to view the running status logs of each device module. These logs can be used to determine if each module is functioning normally.

Inspection Results

Sangfor AD Load Balancer Device Inspection Manual
Sangfor AD Load Balancer Device Inspection Manual

Images localized into English for illustration; labels may vary by product version.

14 views Updated 2026-11-07

More in this groupNetwork & Load Balancer Inspection

View all 8 in this group

Can't find an answer?