Replacing a Failed Hard Drive in an AIX RAID 5 Array

IBM Small Systems Hard Drive Replacement Process: RAID5

I. Symptom Description

One IBM Small System with a RAID controller, containing 3 internal hard drives configured in RAID5 with no hot spare.

The second hard drive is showing a yellow fault indicator light.

II. Perform rootvg backup (mksysb) and data backup (strongly recommended)

After backing up the data, for safety, stop application access to the hard drives.

III. Fault Confirmation

Execute lsdev –Cc pdisk/hdisk and errpt commands to check if the system reports any hard drive errors.

Navigate to diag -> Task selection -> RAID Array Manager ->       

IBM SAS Disk Array Manager -> List IBM SAS Disk Array configuration to check RAID information and pdisk status.

hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB     

pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB       

pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB     

pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB

Confirm the hard drive slot information using the following steps:

Diag->Task Selection->RAID Array Manager->IBM SASDisk Array Manager-> Diagnostics and Recovery Options->SCSI and SCSI RAID Hot Plug Manager-> Identify a Device Attached to a SCSI Hot Swap Enclosure Device    

Select the corresponding hard drive and press F7 to confirm the slot location (the yellow light on the disk is flashing).

IV. Perform Hard Drive Replacement

1) Replace the hard drive using hot plug as follows:

diag?    

Task Selection?    

RAID Array Manager?     

IBM SASDisk Array Manager?    

   Diagnostics and Recovery Options?     

         SCSI and SCSI RAID Hot Plug Manager?     

Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device    

Replace the faulty hard drive and press Enter.

Then press F3 to return to the previous menu level.

       SCSI and SCSI RAID Hot Plug Manager     

         Configure Added/Replaced Devices     

2) After replacing the hard drive, return to

diag->    

Task selection ->     

         RAID Array Manager ->      

IBM SASDisk Array Manager ->    

        List IBM SAS Disk Array configuration     

You can see that the pdiskX status is failed, as shown in the figure below:

3)   hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB     

   pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB       

   pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB     

   pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB     

7) Execute lsdev –Cc pdisk to verify that pdisk0 is available.    

V. Rebuild the RAID

diag->    

Task selection ->     

       RAID Array Manager ->      

IBM SASDisk Array Manager ->    

           Reconstruct a IBM SASDisk Array     

Select the newly created disk. pdisk0 Initiate rebuild (approximately 4 hours required for a 146GB HDD).      

Rebuild progress will be displayed; you may exit the rebuild process to allow it to run in the background.

VI. After rebuild completion, confirm the RAID status is optimal.

diag->    

Task selection ->     

          RAID Array Manager ->      

IBM SASDisk Array Manager ->    

       List IBM SASDisk Array configuration     

VII. Verify the hard drive is functioning correctly and start the applications.