Dell EMC Data Domain Inspection Method

Device Hardware Status Check

Device Indicator Light Status Check

Inspection Requirements

Observe the panel indicator lights for any red alarm signals.

Inspection Method

Go to the rack where the equipment is located in the server room and check the device appearance panel indicator light status information.

Rectification Suggestions

If there are abnormalities in the indicator light status, check whether the device has hardware or software faults based on the indicator light information.

Storage System Status Check

Inspection Requirements

The storage system must be in a normal running state.

Inspection Method

Log in to the virtual tape library via the management IP address using a browser at http://XXX. Open the Status tab to check if Alerts contain warnings, if services contain warnings,

Check if Hardware contains warnings

Dell EMC Data Domain Inspection Method

For a normal device, all alerts and red X marks are 0. If not 0, there is a fault.

Rectification Suggestions

If the storage system is abnormal, check for hardware faults.

Controller Status Check

Inspection Requirements

The controller must be in a normal running state.

Inspection Method

Check whether the controller components are normal via the chassis tab in Hardware on the web interface

Dell EMC Data Domain Inspection Method

Clicking all components once: green indicates normal; red or yellow boxes indicate abnormalities.

Rectification Suggestions

If controller-related alert information exists on the Current Alerts page, select that alert and handle it according to the detailed description and remediation suggestions on the right.

Device Power Supply Running Status Check

Inspection Requirements

Device power supply related components must be in a normal running state.

Inspection Method

Check whether the controller components are normal via the chassis tab in Hardware on the web interface

Dell EMC Data Domain Inspection Method

Rectification Suggestions

If power module-related alert information exists on the Current Alerts page, select that alert and handle it according to the detailed description and remediation suggestions on the right.

Device Control Frame or Hard Drive Frame Running Status Check

Inspection Requirements

The device control frame or hard drive frame must be in a normal running state.

Inspection Method

Check whether the hard drive components are normal via the storage tab in Hardware on the web interface

Dell EMC Data Domain Inspection Method

Disk roles: In-Use and Spare are normal states; faild is a failure state

Rectification Suggestions

If there are alarm messages related to the control frame or disk frame on the Current Alarms page, select the alarm and handle it according to the detailed description and remediation suggestions on the right.

Device Control Frame Battery Operation Status Check

Inspection Requirements

The device control frame battery must be in normal operation status.

Inspection Method

Check whether the battery component is normal via the Chassis tab in Hardware on the web interface; hover the mouse over NVRM.

Dell EMC Data Domain Inspection Method

Battery is charged and enable is normal; faild is a fault.

Rectification Suggestions

If there are alarm messages related to the battery on the Current Alarms page, select the alarm and handle it according to the detailed description and remediation suggestions on the right.

Device Fan Group Operation Status Check

Inspection Requirements

The device fan group must be in normal operation status.

Inspection Method

Check whether the fan components are normal via the Chassis tab in Hardware on the web interface,

Dell EMC Data Domain Inspection Method

Hover the mouse over each fan to display the fan status. OK is normal; faild is a failure state.

Rectification Suggestions

If there are alarm messages related to the fan group on the Current Alarms page, select the alarm and handle it according to the detailed description and remediation suggestions on the right.

Device Disk Operation Status Check

Inspection Requirements

The device disks must be in normal operation status.

Inspection Method

Check whether the disk components are normal via the storage tab in Hardware on the web interface

.

Dell EMC Data Domain Inspection Method

Rectification Suggestions

If there are alarm messages related to the disks on the Current Alarms page, select the alarm and handle it according to the detailed description and remediation suggestions on the right.

Device Host Port Status Operation Status Check

Inspection Requirements

The host port status must be in normal operation status.

Inspection Method

Check whether the port components are normal via the Network and Fibre Channel tabs in Hardware on the web interface

Dell EMC Data Domain Inspection Method
Dell EMC Data Domain Inspection Method

Check the enable status and link status to confirm they are normal.

Rectification Suggestions

If there are alarm messages related to front-end ports on the Current Alarms page, select the alarm and handle it according to the detailed description and remediation suggestions on the right.

Check the operational status of device system services

Check storage pool status

Inspection requirements

Requirement: Check storage pool status.

Inspection method

1. Check storage pool usage via Filesystem in DataManager on the web interface

  1. Dell EMC Data Domain Inspection Method

Rectification suggestions

If storage pool-related alert information exists on the 'Current Alerts' page, select the alert and handle it according to the detailed description and remediation suggestions on the right.

Check VTL service status

Inspection requirements

Requirement: Check VTL status.

Inspection method

Check virtual tape library related components via VTL in DataManager on the web interface

Dell EMC Data Domain Inspection Method
Dell EMC Data Domain Inspection Method

Rectification suggestions

If LUN-related alert information exists on the 'Current Alerts' page, select the alert and handle it according to the detailed description and remediation suggestions on the right.

Check file system service status

Inspection requirements

Check file system service status.

Inspection method

Check CIFS/NFS/DDBoost status via VTL in DataManager on the web interface

Dell EMC Data Domain Inspection Method
Dell EMC Data Domain Inspection Method
Dell EMC Data Domain Inspection Method
Dell EMC Data Domain Inspection Method

Check if any service status shows errors

Rectification suggestions

If consistency group-related alert information exists on the 'Current Alerts' page, select the alert and handle it according to the detailed description and remediation suggestions on the right.