Restoring the Optimal Path for Logical Drives on IBM DS Storage

After a controller or link failure, logical drives on IBM DS5000 may still be accessed via non-preferred controllers. Once the fault is resolved, you can reassign the logical drives to their preferred paths using Storage Manager. The following screenshots are from the official IBM DS5000 manual; the interface shown is Storage Manager 10. For other versions, verify the corresponding menu names in the relevant manuals.

Pre-recovery checks

First, confirm that controllers, host links, and multipathing have returned to normal operation. If the root cause has not been eliminated, logical drives may switch back to non-preferred paths; do not use repeated reassignments as a substitute for troubleshooting.

Recovery in Storage Manager

  1. Open the Subsystem Management window.
  2. Select Advanced → Recovery → Redistribute Logical Drives.
IBM Official Figure 5-95: Menu entry for restoring the preferred path of a logical drive (DS5000)
IBM Official Figure 5-95: Menu entry for restoring the preferred path of a logical drive (DS5000)
  1. Wait for the reassignment to complete, then check the progress and final status.
IBM Official Figure 5-96: Logical drive reassignment progress window
IBM Official Figure 5-96: Logical drive reassignment progress window

Post-recovery verification

The storage should return to Optimal status, and confirm that the paths are available from the host side. Reassigning a large number of LUNs may take considerable time; if non-preferred paths are still reported, continue checking the original fault and the host multipathing configuration.