HPE 3PAR Power Supply Unit (PSU) Alert Handling

Check both power supply unit (PSU) alarms

cgcmd -tc tty -C cage0 -c report_faults -p a

cgcmd -tc tty -C cage0 -c report_faults -p b

########################################################################################

Power Manager faults

PSU 0 fault: "DC under Voltage" Fault LED: OFF, Warning LED: OFF, Shutdown LED: OFF?

Similar to PSU 0 fault

##########################################################################################

Clear it

cgcmd –tc tty –C cage0 -c "clearpsufault 0" –p a

cgcmd –tc tty –C cage0 -c "clearpsufault 0" –p b

If that fails, reseat the corresponding PSU