NetApp Clear Fault Indicator Light (Seven-Step Method)
7-Step Light-Out Procedure
System version is 7-mode 8.0.3
7-step Light-Out Procedure
Observe the FAS/V3200 Fault LEDs after boot, and verify they are off. If the Fault LEDs flash or stay on, then follow the 7-step process below:
1. At the Data ONTAP CLI prompt, issue the "halt -s" command. Please note that this will cause an HA takeover in an HA configuration.
2. Wait for the controller to shut down and power off
3. On the console port, issue a "^G" to switch the console to the SP
4. Log in to the SP
5. At the SP prompt, issue the "system power on" command
6. Issue a "^D" to get back to the Data ONTAP console
7. Once the BIOS / Loader have booted, issue the "boot_ontap" command
For HA configurations, the partner will also need to go through the 7-step process above
Turn off component indicator lights in maintenance mode
priv set diag to enter maintenance mode
fru_led status to check component alarm lights
fru_led off all to turn off all component alarm lights
led_off_all
led_off_all 0c to turn off channel alarm lights
priv set to exit diagnostic mode