xFusion FusionServer iBMC One-Click Information Collection (Contents and diaginfo Command)

FusionServer Server iBMC User Guide

5.10 One-Click Information Collection

NOTE

iBMC V3.02.00.03 and later versions do not support the MD5 integrity check code.

Table 5-105 One-click information collection

File NameFile Content
dump\dump_info
dump_app_logList of information collected by the iBMC.
dump_logList of one-click information collecting result.
sn_history_info sn_history_info.1.gzModification record of product serial number in the FRU information. NOTE iBMC V3.07.01.75 and later versions can collect this information.
dump\dump_info\3rdDump
access_logApache access log.
access_log.1Backup file of the Apache access log.
error_logApache error log.
error_log.1Backup file of the Apache error log.
nginx.confBasic configuration file of Nginx.
nginx_http_server.confConfiguration file of the Nginx HTTP server.
nginx_https_server.confConfiguration file of the Nginx HTTPS server.
nginx_https_server_ext.confExtended configuration file of Nginx.
nginx_https_defualt_server_ext.confExtended configuration file of Nginx HTTPS defualt server.
nginx_ssl_ciphersuite.confConfiguration file of Nginx HTTPS encryption suites.
nginx_ssl_protocol.confConfiguration file of Nginx HTTPS versions.
nginx_ssl_verify_client.confConfiguration file of Nginx two-factor authentication.
dump\dump_info\AppDump
agentless
agentless_dfl.logInformation about the Agentless module.
BIOS
BIOS_dfl.logInformation about the BIOS.
bios_infoBIOS configuration information.
currentvalue.jsonInformation about current BIOS configuration.
registry.jsonBIOS registration file, containing BIOS configuration information.
result.jsonResult of the BIOS settings configured using Redfish.
setting.jsonInformation about the BIOS settings configured using Redfish that have not taken effect.
BMC
BMC_dfl.logInformation about the iBMC module.
lldp_info.txtLLDP configuration and packet statistics.
invalidsnlist.jsonList of Failed Component Qualification.
mcinfo.txtiBMC auxiliary firmware information.
nandflash_info.txtNAND flash information.
net_info.txtInformation about network interface configuration.
ntp_info.txtError information about NTP synchronization failure.
psu_info.txtInformation about the PSUs of the server.
time_zone.txtiBMC time zone information.
card_manage
aim_bmc_sensor_logOriginal response data for a Redfish request from the module BMC sensor. NOTE iBMC V3.07.05.01 and later versions support this log.
aimodule_log.tar.gzLog information of the AI module.
card_infoInformation about the cards configured on the server.
card_manage_dfl.logInformation about the Card_Manage module.
gpu.logGPU card memory ECC information. NOTE iBMC V3.08.07.03 and later versions support this log.
Pciecardn_registerRegister information of the PCIe card. NOTE ● Servers configured with Gaudi 2E cards support collection of this log information. ● n indicates the slot number of the PCIe card.
profile.tar.gzInformation about the cards supported by the server. NOTE iBMC V3.08.07.05 and later versions support this log.
sdi_card_cpld_infoInformation about the CPLD register of the SDI V3 card. NOTE This information can be collected only when the SDI V3 card is supported and correctly installed.
sl200_card_reg_infoInformation about the register of the SL200 accelerator card. NOTE This information can be collected only when the SL200 accelerator card is supported and correctly installed.
cooling_app
cooling_app_dfl.logInformation about the Cooling module.
cooling_cfg.log cooling_cfg.log.1.gzConfiguration files for fan speed regulation.
cooling_running_log.csv cooling_running_log.csv.1.gzProcess files for fan speed regulation.
fan_info.txtInformation about the fan models and rotation speed.
CpuMem
cpu_infoDetailed information about the CPUs configured for the server.
CpuMem_dfl.logInformation about the CpuMem module.
mem_infoDetailed information about the DIMMs configured for the server.
ddns
ddns_dfl.logInformation about the DDNS module.
dfm
dfm.logInformation about the objects managed by the DFM.
dfm_debug_log dfm_debug_log.1 ……PME frame debugging log.
Dft
Dft_dfl.logInformation about the DFT module.
diagnose
diagnose_dfl.logInformation about the Diagnose module.
diagnose_infoPort 80 fault diagnosis information and memory usage of the IFMM module.
discovery
discovery_dfl.logInformation about the Discovery module.
FileManage
FileManage_dfl.logInformation about the FileManage module.
FruData
FruData_dfl.logInformation about the FruData module.
fruinfo.txtFRU electronic label information.
Part name_info.txtEEPROM information of parts that support electronic labels. The file size is fixed at 16 KB.
ipmi_app
ipmbeth_info.txtInformation about the status of the IPMI channels of the management system.
ipmi_app_dfl.logInformation about the IPMI module.
kvm_vmm
kvm_vmm_dfl.logInformation about the KVM_VMM module.
Lcd
Lcd_dfl.logInformation about the LCD module.
LicenseMgnt
alm_protected.persistPersistency file of the license management component ALM.
first_protected.persistPersistency file of the license management component ALM.
LicenseMgnt_dfl.logManaged object information.
lm_infoInformation including the license status and device ESN.
second_protected.persistPersistency file of the license management component ALM.
MaintDebug
MaintDebug_dfl.logInformation about the MaintDebug module.
MCTP
MCTP_dfl.logInformation about the MCTP module.
mctp_infoInformation about MCTP.
net_nat
net_nat_dfl.logInformation about the Net_NAT module.
NetConfig
dhclient.log dhclient.log.1.gzDHCP logs. NOTE iBMC V3.07.01.89 and later versions can collect this information.
lldp_info.txtLLDP configuration and packet statistics.
net_info.txtInformation about network interface configuration.
NetConfig_dfl.logInformation about the NetConfig module.
Payload
Payload_dfl.logInformation about the Payload module.
PcieSwitch
PcieSwitch_dfl.logInformation about the PCIeSwitch module.
pcieswitch_infoLog information of the PCIeSwitch module.
pcieswitch_keyreg_dataPCIeSwitch key register information.
RetimerRegInfoRetimer chip registry information.
portal
portal_dfl.logInformation about the portal module.
PowerMgnt
power_statistics.csvPower statistic information.
power_bbu_info.logBBU logs (only for the server that supports BBUs).
PowerMgnt_dfl.logInformation about the PowerMgnt module.
redfish
component_uri.jsonComponent URI list.
event_sender_info.logError notice shown when the Redfish subscription message is sent.
redfish_dfl.logInformation about the Redfish module.
rimm
rimm_dfl.logInformation about the StorageMgnt module.
sensor_alarm
current_event.txtCurrent health status and alarms of the server.
LedInfoCurrent indicator status of the server.
sel.dbDatabase information of the current SELs.
sel.tarCompressed package of current and historical system event logs (SELs).
sensor_alarm_dfl.logInformation about the Sensor_Alarm module.
sensor_alarm_sel.binOriginal information and check value of the current SELs.
sensor_alarm_sel.bin.bakOriginal backup information and check value of the current SELs.
sensor_alarm_sel.bin.bak.sha256Integrity check code for the backup of original SELs.
sensor_alarm_sel.bin.sha256Integrity check code for original SELs.
sensor_alarm_sel.bin.tar.gzCompressed package of historical SELs.
sensor_info.txtList of all sensors of the server.
Smm_Mgnt
Smm_Mgnt_dfl.logInformation about the Smm_Mgnt modules.
Snmp
Snmp_dfl.logInformation about the Snmp module.
SPDM
spdm_dfl.logInformation on the SPDM module management object.
*_importUser-imported SPDM baseline metrics.
afm_ca_hash.jsonSHA256 value of the stored file.
StorageMgnt
PhysicalDrivesInfoHard drive history information folder. The sub-folders are named after the hard drives, for example, Disk0\disk_info. NOTE iBMC V3.07.00.77 and later versions can collect this information.
RAID_Controller_Info.txtInformation about the RAID controller card, logical drives, and hard drives.
StorageMgnt_dfl.logInformation about the StorageMgnt module.
switch_card
phy_register_infoInformation about the PHY registry of the rear boards.
port_adapter_infoInformation about the interface device of the rear boards.
switch_card_dfl.logInformation about the Switch_Card module.
UPGRADE
UPGRADE_dfl.logInformation about the Upgrade module.
upgrade_infoVersion information about the devices related to the iBMC.
User
User_dfl.logInformation about the User module.
usb_mgmt
usb_mgmt_dfl.logInformation about the USB module.
dump\dump_info\BMALogDump
bma_debug_log bma_debug_log.1.gz bma_debug_log.2.gz bma_debug_log.3.gziBMA logs.
dump\dump_info\CoreDump
core-* (files starting with "core-".)Memory dump file. It is the core dump file of an application program. One or more files are generated, depending on the system running status.
dump\dump_info\DeviceDump
i2c_info
*_infoI2C device memory or storage area information.
dump\dump_info\LogDump
crashdump
crashdump*.tar.gzFDM TOR logs. NOTE Servers configured with Intel processors support collection of this log information.
ras_error_*.cperCrashdump information when a system error or a system fault occurs. NOTE ● A maximum of 10 latest .cper files can be collected. ● Servers configured with AMD processors support collection of this log information.
EyeTest
Eye-Board Name-Switchn.jsonPCIe Switch eye diagram test result data. NOTE ● iBMC V3.09.03.01 and later versions can collect this information. ● n indicates the Switch number on the board.
M3LogDump
m3_log m3_log.1 ……M3 logs.
netcard
netcard_info.txt netcard_info_bk.txtNIC configuration information.
pciecard
SDI log folder (SDI V3 and earlier versions), named in the SDI card slot number_SDI card name format, for example, pciecard5_IT21SHSG.●fw_bios_log.bin: BIOS logs of the SDI card. ●fw_imu_log.bin: Intelligent management unit (IMU) logs of the SDI card. ●fw_last_log.bin: Lastword logs of the SDI card. ●fw_M7_log.bin: M7 logs of the SDI card.
The log folder of SDI card (SDI V5.1 version) is named as PCIeCard1(SDIV5.1)_SDI5.1.●error_log_SDIV5.1.bin: Log files of SDI card OS. ●error_log_SDIV5.1.bin.1.gz: Log files of SDI card OS in compressed package.
sdi_blackboxSDI black box log folder. NOTE The log information can be collected only after the SDI black box data files have been downloaded from the Diagnostics screen.
PCIe card log folder, named in the PCIe card name and slot number_PCIe card model format, for example, "PCIeCard6_SP570".All PCIe card logs, including CPLD register information, error logs, last words, and preventive maintenance inspection logs. Example: ● cpld.log ● last_word_20160211182849 ● error_log_20160211182532 ● running_log_20160211183202
Retimer
Retimer log folder, which is named after the retimer object. For example, Cdr5902H_Obj_1-10.Retimer log information, including: ●PCIe: PCIe command output information ●RAMLog: logs exported from the SRAM ●SerDes: SerDes information
runtimeerror
dram_runtime_*.cperMemory error information during system runtime.
mca_runtime_*.cperMCA error information during system runtime.
storage
*_com_log *_com_log.1.gz ……RAID card serial port log, for example, RAID_Card1_com_log.
ctrllogA folder containing all RAID controller cards logs. The sub-folders are named after the RAID controller cards. ●Raw log content of the RAID controller card's AP firmware: "ap.bin". ●Raw log content of the RAID controller card's IMU firmware: "imu.bin". ●Log parsing dictionary of the RAID controller card's AP firmware: "ap_index.gz". ●Log parsing dictionary of the RAID controller card's IMU firmware: "imu_index.gz". ●Raw data of power-off notice of the RAID controller card AP firmware: "lastword.bin". ●Raw data of statistics on the RAID controller card AP firmware: "dump.bin". ●Raw flash data of statistics on the RAID controller card AP firmware: "flash_dump.bin". ●Raw Nand flash log data of the RAID controller card: "0nandlog.bin" and "1nandlog.bin".
drivelogA folder containing all SAS and SATA hard drive logs. The sub-folders are named after the hard drives, for example, Disk0. ●SATA hard drive logs, for example, SATA_Log, SMARTAttribute, SeagateFARMLog ●SAS hard drive logs, for example, SAS_Log and SAS_Log.1
phyA folder containing PHY error code logs of all RAID controller cards and the expanders on the RAID controller card. The sub- folders are named after the RAID controller cards, for example, RAID_Card1. ●RAID controller card PHY error code log, for example, RAID_Card1_PHY_Error_Count.csv ●Expander PHY error code log, for example, RAID_Card1_Expander1_PHY_Error_ Count.csv
storage\storelib
storelib_debug_log storelib_debug_log.1 ……Storelib library logs.
storelib8debug.txt storelib8debug.txt.1 ……Storelib8 library logs.
storelibit_debug_log storelibit_debug_log.1 ……Storelibit library logs.
storelibir3_debug_log storelibir3_debug_log.1 ……Storelibir3 library logs.
dump\dump_info\LogDump
agentless_driver_log agentless_driver_log.1.gz agentless_driver_log.2.gz agentless_driver_log.3.gz ……Agentless driver debug logs.
app_debug_log_all app_debug_log_all.1.gz app_debug_log_all.2.gz app_debug_log_all.3.gzApp Debug logs.
bmc_cpu_usage_info.log bmc_cpu_usage_info.log.1.gzCPU usage information of the BMC (recorded when the CPU usage exceeds 70%). NOTE iBMC V3.07.01.51 and later versions can collect this information.
bmccom.datBMC serial port log.
bmccom_YYYYMMDD-HHmm.datBMC serial port log. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off).
systemcom_YYYYMMDD- HHmm.datSOL serial port information. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off).
BMCResetRecord.logBMC restart record.
compliance_prompt_logCompliance prompt log.
config_operate_log config_operate_log.tar.gzUser configuration operation log. NOTE V5/V6 servers support the collection of this log information in iBMC V3.07.03.63 and later versions. V7/V8 servers support this collection by default.
corefileCore dump files.
CpuTempLogRecords_CPUn_COR ETEMP.csv CpuTempLogRecords_CPUn_COR ETEMP.csv.1.gz CpuTempLogRecords_CPUn_COR ETEMP.csv.2.gz CpuTempLogRecords_CPUn_COR ETEMP.csv.3.gzCore temperature of CPUn. The file data format is: timestamp, scan interval (in milliseconds), data1, data2, data3…… NOTE n indicates the CPU number.
CpuTempLogRecords_CPUn_MAX MEMTEMP.csv CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.1.gz CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.2.gz CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.3.gzMaximum temperature of the memory channels of CPUn. The file data format is: timestamp, scan interval (in milliseconds), data1, data2, data3…… NOTE n indicates the CPU number.
cpun_m7_log cpun_m7_log.tar.gzM7 coprocessor run log of CPU (only for the server that supports M7 coprocessor).
dfx_log dfx_log.tar.gzDFX register information.
fdm.bin fdm.bin.tar.gzLog of FDM original faults.
fdm_log fdm_log.tar.gzFDM logs.
fdm_me_log fdm_me_log.tar.gzLog of ME faults.
fdm_mmio_log fdm_mmio_log.tar.gzFDM board configuration logs.
fdm_output fdm_output.1.gz fdm_output.2.gz fdm_output.3.gzFDM logs.
fdm_pfae_logLog of FDM perwarnings.
imu_log imu_log.tar.gzIMU run log (only for the server that supports IMU).
ipmi_debug_log ipmi_debug_log.tar.gzIPMI module logs.
ipmi_mass_operate_log ipmi_mass_operate_log.tar.gzIPMI module operation logs.
kvm_vmm_debug_log kvm_vmm_debug_log.tar.gzKVM module logs.
LSI_RAID_Controller_Log LSI_RAID_Controller_Log.1.gz LSI_RAID_Controller_Log.2.gzLogs of the LSI RAID controller.
PD_SMART_INFO_C*SMART log of hard disks. * indicates the serial number of the RAID controller.
linux_kernel_log linux_kernel_log.1 ……Linux kernel logs.
log_records_info-2.csvRecords the number of times the voltage is lower than the alarm threshold.
maintenance_log maintenance_log.tar.gzMaintenance logs.
mass_operate_log mass_operate_log.tar.gz operate_log operate_log.tar.gzUser operation log.
pcieswcom.datPCIe switch logs. NOTE ● G8600 V7 iBMC V3.07.02.25 and later versions support collection of this log information. ● GN560E V7 iBMC V3.08.03.01 and later versions support collection of this log information.
PD_SMART_INFO_C0SMART information for SATA drives or sense information for SAS drives.
preserve.logLogs of firmware upgrade without configuration retention.
ps_black_box.log ps_black_box.log.1.gz ps_black_box.log.2.gz ps_black_box.log.3.gzPower supply black box logs.
remote_log remote_log.1.gzOperation logs and SEL logs for Syslog test.
security_log security_log.1Security logs.
strategy_log strategy_log.tar.gzSystem running logs.
telemetry_logservice_offsetTelemetry logservice offset information.
telemetryLogTelemetryLog information.
third_party_file_bak.logLogs of third-party file backup.
uart3com.datVoice recording file of uart3.
uart3com_YYYYMMDD-HHmm.datVoice recording file of uart3. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off).
uart4com.datVoice recording file of uart4.
uart4com_YYYYMMDD-HHmm.datVoice recording file of uart4. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off).
dump\dump_info\OptPme
pram NOTE This folder contains files from the /opt/pme/pram directory. The files that are not included in this folder are intermediate files generated during the running of the program and have no information security issues.
filelistList of files in the /opt/pme/pram directory.
lost+foundFolder.
proc_queueProcess queue ID folder.
semidProcess semaphore ID folder.
up_cfgUpgrade configuration folder.
BIOS_FileNameSMBIOS information.
BIOS_OptionFileNameBIOS configuration information.
BMC_dhclient.confDHCP configuration file.
BMC_dhclient.conf.sha256Integrity check code.
BMC_dhclient_ip.confDHCP configuration file.
BMC_dhclient_ip.conf.sha256Integrity check code.
BMC_dhclient6.confDHCP configuration file.
BMC_dhclient6.conf.sha256Integrity check code.
BMC_dhclient6_ip.conf.sha256Integrity check code.
BMC_HOSTNAMEHost name.
BMC_HOSTNAME.sha256Integrity check code.
cpu_utilise_webview.datCPU usage curve data.
CpuMem_cpu_utiliseServer CPU usage.
CpuMem_mem_utiliseServer memory usage.
CpuMem_mem_os_utiliseServer memory usage.
env_web_view.datAmbient temperature curve data.
eo.dbSEL database.
fan_speed_webview.datFan speed log.
fdm_history.dbFDM health analysis engine database.
fdm_history.db.sha256Integrity check code.
fdm_history.db.sha256_backupIntegrity check code.
fdm_history.db_backupFDM health analysis engine database.
filelistList of files in the /opt/pme/pram directory.
fsync_reg.iniFile synchronization configuration file.
lost+foundFolder.
io_utilise_webview.datIO usage curve data.
md_so_maintenance_log md_so_maintenance_log.tar.gzMaintenance logs.
md_so_operate_log md_so_operate_log.tar.gz md_so_mass_operate_log md_so_mass_operate_log.tar.gzUser operation log.
md_so_operate_log.sha256Integrity check code.
md_so_strategy_log md_so_strategy_log.tar.gzPolicy log.
md_so_strategy_log.sha256Integrity check code.
memory_os_webview.datMemory usage curve data.
NetConfig_dhclient.confDHCP configuration file.
NetConfig_dhclient_ip.confDHCP configuration file.
per_config.iniiBMC configuration persistence file.
per_config.ini.sha256Integrity check code.
per_config_permanent.iniiBMC configuration persistence file.
per_config_permanent.ini.sha256Integrity check code.
per_config_reset.iniiBMC configuration persistence file.
per_config_reset.ini.bakiBMC configuration persistence file.
per_config_reset.ini.bak.sha256Integrity check code.
per_config_reset.ini.sha256Integrity check code.
per_def_config.iniiBMC configuration persistence file.
per_def_config.ini.sha256Integrity check code.
per_def_config_permanent.iniiBMC configuration persistence file.
per_def_config_permanent.ini.sha2 56Integrity check code.
per_def_config_reset.iniiBMC configuration persistence file.
per_def_config_reset.ini.bakiBMC configuration persistence file.
per_def_config_reset.ini.bak.sha256Integrity check code.
per_def_config_reset.ini.sha256Integrity check code.
per_power_off.iniiBMC configuration persistence file.
per_power_off.ini.sha256Integrity check code.
per_reset.iniiBMC configuration persistence file.
per_reset.ini.bakiBMC configuration persistence file.
per_reset.ini.bak.sha256Integrity check code.
per_reset.ini.sha256Integrity check code.
pflash_lockFlash file lock.
PowerMgnt_recordManaged object operating information.
powerview.txtPower statistic file.
proc_queueProcess queue ID folder.
ps_web_view.datManaged object operating information.
sel.dbSEL database.
sel_db_syncSEL database synchronization lock.
semidProcess semaphore ID folder.
sensor_alarm_sel.binOriginal SEL file.
sensor_alarm_sel.bin.sha256Integrity check code.
sensor_alarm_sel.bin.tar.gzCompressed package of historical SELs.
Snmp_http_configureHTTP configuration folder.
Snmp_http_configure.sha256Integrity check code.
Snmp_https_configureHTTPS configuration folder.
Snmp_https_configure.sha256Integrity check code.
Snmp_https_tslHTTPS TLS configuration folder.
Snmp_https_tsl.sha256Integrity check code.
Snmp_snmpd.confSnmp configuration backup file
Snmp_snmpd.conf.sha256Integrity check code.
up_cfgUpgrade configuration folder.
User_loginLogin PAM login rules.
User_login.sha256Integrity check code.
User_sshdSSH PAM login rules.
User_sshd.sha256Integrity check code.
User_sshd_configSSH configuration file.
User_sshd_config.sha256Integrity check code.
User_vsftpFTP PAM login rules.
User_vsftp.sha256Integrity check code.
save NOTE This folder contains files from the /opt/pme/save directory. The *.sha256 file contains the integrity check code. The *.bak file is the backup file. The *.tar.gz file is a compressed file package. The per_*.ini file is a configuration persistence file. The *sel.* is a system event log file. (The files that are not included in this folder are intermediate files generated during the running of the program and have no information security issues.)
filelistList of files in the /opt/pme/pram directory.
BIOS_FileNameSMBIOS information.
BMC_dhclient.conf.bakDHCP configuration backup file.
BMC_dhclient.conf.bak.sha256Integrity check code.
BMC_dhclient.conf.sha256Integrity check code.
BMC_dhclient_ip.conf.bakDHCP configuration backup file.
BMC_dhclient_ip.conf.bak.sha256Integrity check code.
BMC_dhclient_ip.conf.sha256Integrity check code.
BMC_dhclient6.conf.bakDHCP configuration backup file.
BMC_dhclient6.conf.bak.sha256Integrity check code.
BMC_dhclient6.conf.sha256Integrity check code.
BMC_dhclient6_ip.conf.bakDHCP configuration backup file.
BMC_dhclient6_ip.conf.bak.sha256Integrity check code.
BMC_dhclient6_ip.conf.sha256Integrity check code.
BMC_HOSTNAME.bakHost name configuration backup file.
BMC_HOSTNAME.bak.sha256Integrity check code.
BMC_HOSTNAME.sha256Integrity check code.
CpuMem_cpu_utiliseManaged object operating information.
CpuMem_mem_utiliseManaged object operating information.
eo.dbSEL database.
eo.db.sha256Integrity check code.
eo.db.sha256_backupIntegrity check code.
eo.db_backupSEL database.
fdm_history.dbFDM health analysis engine database.
fdm_history.db.sha256Integrity check code.
fdm_history.db.sha256_backupIntegrity check code.
fdm_history.db_backupFDM health analysis engine database.
filelistList of files in the /opt/pme/pram directory.
md_so_config_operate_log.bakUser configuration operation log.
md_so_config_operate_log.bak.sha 256Integrity check code.
md_so_config_operate_log.sha256Integrity check code.
md_so_operate_log.bakUser operation log
md_so_operate_log.bak.sha256Integrity check code.
md_so_operate_log.sha256Integrity check code.
md_so_strategy_log.bakPolicy log.
md_so_strategy_log.bak.sha256Integrity check code.
md_so_strategy_log.sha256Integrity check code.
NetConfig_dhclient.conf.bakDHCP configuration backup file.
NetConfig_dhclient_ip.conf.bakDHCP configuration backup file.
per_config.iniiBMC configuration persistence file.
per_config.ini.bakiBMC configuration persistence file.
per_config.ini.bak.sha256Integrity check code.
per_config.ini.sha256Integrity check code.
per_def_config.iniiBMC configuration persistence file.
per_def_config.ini.bakiBMC configuration persistence file.
per_def_config.ini.bak.sha256Integrity check code.
per_def_config.ini.sha256Integrity check code.
per_power_off.iniiBMC configuration persistence file.
per_power_off.ini.bakiBMC configuration persistence file.
per_power_off.ini.bak.sha256Integrity check code.
per_power_off.ini.sha256Integrity check code.
PowerMgnt_recordManaged object operating information.
sensor_alarm_sel.binOriginal information and check value of the current SELs.
sensor_alarm_sel.bin.bakOriginal information and check value of the current SELs.
sensor_alarm_sel.bin.bak.sha256Integrity check code.
sensor_alarm_sel.bin.sha256Integrity check code.
sensor_alarm_sel.bin.tar.gzCompressed package of historical SELs.
Snmp_http_configure.bakHTTP configuration backup file.
Snmp_http_configure.bak.sha256Integrity check code.
Snmp_http_configure.sha256Integrity check code.
Snmp_https_configure.bakHTTPS configuration backup file.
Snmp_https_configure.bak.sha256Integrity check code.
Snmp_https_configure.sha256Integrity check code.
Snmp_https_tsl.bakHTTPS TLS configuration backup file.
Snmp_https_tsl.bak.sha256Integrity check code.
Snmp_https_tsl.sha256Integrity check code.
Snmp_snmpd.conf.bakSnmp configuration backup file.
Snmp_snmpd.conf.bak.sha256Integrity check code.
Snmp_snmpd.conf.sha256Integrity check code.
User_login.bakLogin PAM login rules
User_login.bak.sha256Integrity check code.
User_login.sha256Integrity check code.
User_sshd.bakSSH PAM login rules
User_sshd.bak.sha256Integrity check code.
User_sshd.sha256Integrity check code.
User_sshd_config.bakSSH configuration file.
User_sshd_config.bak.sha256Integrity check code.
User_sshd_config.sha256Integrity check code.
User_vsftp.bakFTP PAM login rules
User_vsftp.bak.sha256Integrity check code.
User_vsftp.sha256Integrity check code.
dump\dump_info\OSDump
*.repVideo files automatically recorded. NOTE If a video file exceeds 21 MB, you are advised to download and save it to the local PC. The iBMC will delete the video file larger than 21 MB during one-click information collection.
bsod_auto.jpegOS screenshot.
img*.jpegImage of the last screenshot of the server OS.
systemcom.tarSOL serial port information.
video_caterror_rep_is_deleted.infoInformation prompting users to delete oversized caterror video files.
dump\dump_info\Register
cpld_reg_infoComplex programmable logical device (CPLD) register information.
xxx_xxx_cpld_reg_infoInformation about CPLD registers. The file naming format is device type_device name_cpld_reg_info. For example, Disk_BP3BC15HBBA_cpld_reg_info. (Including midplane and module.)
lsw_reg_infoInformation about LSW registers.
phy_reg_infoInformation about PHY registers.
cpu_reg_infoCPU register information.
oem_sensor_infoSecondary sensor information file.
vrm_reg_infoInformation about VRM registers.
dump\dump_info\RTOSDump
driver_info
cdev_drv_infoThe statistics of character device driver.
dmesg_infoSystem startup information (execution result of dmesg).
edma_drv_infoThe statistics of edma driver.
kbox_infokbox information.
lsmod_infoInformation about loaded drivers.
veth_drv_infoThe statistics of virtual network card driver.
networkinfo
_data_var_dhcp_dhclient.leasesDHCP lease file.
dhclient.confDHCP configuration file.
dhclient.leasesDHCP lease file.
dhclient_ip.confDHCP configuration file.
dhclient6.confDHCP configuration file.
dhclient6.leasesDHCP lease file.
dhclient6_eth0.leasesDHCP lease file.
dhclient6_eth1.leasesDHCP lease file.
dhclient6_eth2.leasesDHCP lease file.
dhclient6_ip.confDHCP configuration file.
ifconfig_infoNetwork information. You can run the ifconfig command to obtain it.
ipinfo_infoiBMC network configuration information.
netstat_infonetstat -a Displays the current network ports and connection status.
resolv.confDNS configuration file.
route_inforoute Displays the current routing information.
servicesService port information.
other_info
datafs_logThe data check log.
extern.confiBMC log file configuration.
loginLogin PAM login rules.
logrotate.statusFile recording the logrotate status.
ntp.confNTP service configuration.
pam_faillockPAM error message.
pam_tally2User lockout policy upon an iBMC login failure.
remotelog.confSyslog configuration file.
sshSSH service configuration.
sshdSSH PAM login rules.
sshd_configSSHD service configuration file.
vsftpdFTP PAM login rules.
sysinfo
cmdlineKernel command line parameters.
cpuinfoInformation about the CPU chip of the iBMC kernel.
devicesiBMC device information.
df_infoInformation about the usage of the iBMC partitions.
diskstatsInformation about the iBMC drive status.
filesystemsiBMC file system information.
free_infoInformation about available iBMC memory.
interruptsiBMC interrupt information.
ipcs_qiBMC process queue information.
ipcs_q_detailDetailed information about the iBMC process queue.
ipcs_siBMC process semaphore information.
ipcs_s_detailDetailed information about the iBMC process semaphore.
loadavgiBMC system workload information.
locksList of iBMC kernel lock files.
meminfoiBMC memory usage information.
modulesList of iBMC modules.
mtdInformation about the iBMC configuration partition.
partitionsInformation about the iBMC partitions.
ps_infops -elf Displays detailed information about iBMC processes.
slabinfoInformation about the iBMC slab information.
statCPU usage of the iBMC.
top_infotop -bn 1 Displays the current process running information.
uname_infouname -a Displays current status of the iBMC processes.
uptimeiBMC system operating time
versionReal-time operating system (RTOS) version of the iBMC.
vmstatiBMC virtual memory statistical information.
versioninfo
app_revision.txtiBMC version information.
build_date.txtTime when the iBMC version was built.
fruinfo.txtFRU electronic label information.
ibmc_revision.txtiBMC revision information.
RTOS-ReleaseRTOS release information.
RTOS-RevisionRTOS version markup.
server_config.txtCurrent configuration information of the server.
dump\dump_info\SpLogDump NOTE The logs cannot be collected during the SP running process.
iBMALogDumpiBMA log folder.
configThis log information can be collected only after the SP is running. NOTE The logs can be collected after the configuration is exported on the SP.
upgradeFirmware upgrade log folder.
component_version.jsonConfiguration file of the Smart Provisioning component package version.
deviceinfo.jsonServer asset information.
diagnoseHardware diagnostics log. NOTE The logs can be collected after hardware diagnosis is performed on the SP.
dmesg.log dmesg.tar.gzdmesg logs of the small system.
SPCfglog.tar.gzSPCfg log. NOTE The logs can be collected after the configuration is exported on the SP.
filepatchup_debug.logQuick deployment file packaging logs. NOTE The logs can be collected after SP quick deployment is performed.
images.logQuick deployment clone logs. NOTE The logs can be collected after SP quick deployment is performed.
images_restore.logQuick deployment rollback logs. NOTE The logs can be collected after SP quick deployment is performed.
maintainlog.csv maintainlog.tar.gzSP maintenance log. The maintainlog files with timestamps are logs collected earlier.
operatinglog.csvSP operating log. The operatinglog files with timestamps are logs collected earlier.
ping6.log ping6.tar.gzNetwork communication logs.
quickdeploy_debug.logQuick deployment logs. NOTE The logs can be collected after SP quick deployment is performed.
rollback_version.iniVersion that supports component package rollback.
sp_upgrade_info.logSP self-upgrade logs. NOTE The logs can be collected after SP self-upgrade is performed.
upgrade.logSP firmware update logs.
upgrade_result.jsonUpgrade result logs.
varmesg.log syslog.tar.gzSmall system information logs.
version.jsonSP version information.
version.json.*Verification file of the SP version configuration file.

6.8.17 Performing One-Click Information Collection (diaginfo)

Function

The diaginfo command is used to collect information in one-click mode, including iBMC configuration information, version information, and logs. For more details, see 5.10 One-Click Information Collection.

Format

ipmcget -d diaginfo

Parameters

None

Usage Guidelines

To view the collected information, use a file transfer tool that supports SFTP, for example WinSCP, to transfer the file (for example dump_info.tar.gz) from the /tmp directory to the local PC.

Example

# Perform one-click information collection.

iBMC:/->ipmcget -d diaginfo
Downloading... 100%
Download diagnose info to /tmp/ successfully.
2 views Updated 2026-11-08