xFusion FusionServer iBMC One-Click Information Collection (Contents and diaginfo Command)
FusionServer Server iBMC User Guide
5.10 One-Click Information Collection
NOTE
iBMC V3.02.00.03 and later versions do not support the MD5 integrity check code.
Table 5-105 One-click information collection
| File Name | File Content |
|---|---|
| dump\dump_info | |
| dump_app_log | List of information collected by the iBMC. |
| dump_log | List of one-click information collecting result. |
| sn_history_info sn_history_info.1.gz | Modification record of product serial number in the FRU information. NOTE iBMC V3.07.01.75 and later versions can collect this information. |
| dump\dump_info\3rdDump | |
| access_log | Apache access log. |
| access_log.1 | Backup file of the Apache access log. |
| error_log | Apache error log. |
| error_log.1 | Backup file of the Apache error log. |
| nginx.conf | Basic configuration file of Nginx. |
| nginx_http_server.conf | Configuration file of the Nginx HTTP server. |
| nginx_https_server.conf | Configuration file of the Nginx HTTPS server. |
| nginx_https_server_ext.conf | Extended configuration file of Nginx. |
| nginx_https_defualt_server_ext.conf | Extended configuration file of Nginx HTTPS defualt server. |
| nginx_ssl_ciphersuite.conf | Configuration file of Nginx HTTPS encryption suites. |
| nginx_ssl_protocol.conf | Configuration file of Nginx HTTPS versions. |
| nginx_ssl_verify_client.conf | Configuration file of Nginx two-factor authentication. |
| dump\dump_info\AppDump | |
| agentless | |
| agentless_dfl.log | Information about the Agentless module. |
| BIOS | |
| BIOS_dfl.log | Information about the BIOS. |
| bios_info | BIOS configuration information. |
| currentvalue.json | Information about current BIOS configuration. |
| registry.json | BIOS registration file, containing BIOS configuration information. |
| result.json | Result of the BIOS settings configured using Redfish. |
| setting.json | Information about the BIOS settings configured using Redfish that have not taken effect. |
| BMC | |
| BMC_dfl.log | Information about the iBMC module. |
| lldp_info.txt | LLDP configuration and packet statistics. |
| invalidsnlist.json | List of Failed Component Qualification. |
| mcinfo.txt | iBMC auxiliary firmware information. |
| nandflash_info.txt | NAND flash information. |
| net_info.txt | Information about network interface configuration. |
| ntp_info.txt | Error information about NTP synchronization failure. |
| psu_info.txt | Information about the PSUs of the server. |
| time_zone.txt | iBMC time zone information. |
| card_manage | |
| aim_bmc_sensor_log | Original response data for a Redfish request from the module BMC sensor. NOTE iBMC V3.07.05.01 and later versions support this log. |
| aimodule_log.tar.gz | Log information of the AI module. |
| card_info | Information about the cards configured on the server. |
| card_manage_dfl.log | Information about the Card_Manage module. |
| gpu.log | GPU card memory ECC information. NOTE iBMC V3.08.07.03 and later versions support this log. |
| Pciecardn_register | Register information of the PCIe card. NOTE ● Servers configured with Gaudi 2E cards support collection of this log information. ● n indicates the slot number of the PCIe card. |
| profile.tar.gz | Information about the cards supported by the server. NOTE iBMC V3.08.07.05 and later versions support this log. |
| sdi_card_cpld_info | Information about the CPLD register of the SDI V3 card. NOTE This information can be collected only when the SDI V3 card is supported and correctly installed. |
| sl200_card_reg_info | Information about the register of the SL200 accelerator card. NOTE This information can be collected only when the SL200 accelerator card is supported and correctly installed. |
| cooling_app | |
| cooling_app_dfl.log | Information about the Cooling module. |
| cooling_cfg.log cooling_cfg.log.1.gz | Configuration files for fan speed regulation. |
| cooling_running_log.csv cooling_running_log.csv.1.gz | Process files for fan speed regulation. |
| fan_info.txt | Information about the fan models and rotation speed. |
| CpuMem | |
| cpu_info | Detailed information about the CPUs configured for the server. |
| CpuMem_dfl.log | Information about the CpuMem module. |
| mem_info | Detailed information about the DIMMs configured for the server. |
| ddns | |
| ddns_dfl.log | Information about the DDNS module. |
| dfm | |
| dfm.log | Information about the objects managed by the DFM. |
| dfm_debug_log dfm_debug_log.1 …… | PME frame debugging log. |
| Dft | |
| Dft_dfl.log | Information about the DFT module. |
| diagnose | |
| diagnose_dfl.log | Information about the Diagnose module. |
| diagnose_info | Port 80 fault diagnosis information and memory usage of the IFMM module. |
| discovery | |
| discovery_dfl.log | Information about the Discovery module. |
| FileManage | |
| FileManage_dfl.log | Information about the FileManage module. |
| FruData | |
| FruData_dfl.log | Information about the FruData module. |
| fruinfo.txt | FRU electronic label information. |
| Part name_info.txt | EEPROM information of parts that support electronic labels. The file size is fixed at 16 KB. |
| ipmi_app | |
| ipmbeth_info.txt | Information about the status of the IPMI channels of the management system. |
| ipmi_app_dfl.log | Information about the IPMI module. |
| kvm_vmm | |
| kvm_vmm_dfl.log | Information about the KVM_VMM module. |
| Lcd | |
| Lcd_dfl.log | Information about the LCD module. |
| LicenseMgnt | |
| alm_protected.persist | Persistency file of the license management component ALM. |
| first_protected.persist | Persistency file of the license management component ALM. |
| LicenseMgnt_dfl.log | Managed object information. |
| lm_info | Information including the license status and device ESN. |
| second_protected.persist | Persistency file of the license management component ALM. |
| MaintDebug | |
| MaintDebug_dfl.log | Information about the MaintDebug module. |
| MCTP | |
| MCTP_dfl.log | Information about the MCTP module. |
| mctp_info | Information about MCTP. |
| net_nat | |
| net_nat_dfl.log | Information about the Net_NAT module. |
| NetConfig | |
| dhclient.log dhclient.log.1.gz | DHCP logs. NOTE iBMC V3.07.01.89 and later versions can collect this information. |
| lldp_info.txt | LLDP configuration and packet statistics. |
| net_info.txt | Information about network interface configuration. |
| NetConfig_dfl.log | Information about the NetConfig module. |
| Payload | |
| Payload_dfl.log | Information about the Payload module. |
| PcieSwitch | |
| PcieSwitch_dfl.log | Information about the PCIeSwitch module. |
| pcieswitch_info | Log information of the PCIeSwitch module. |
| pcieswitch_keyreg_data | PCIeSwitch key register information. |
| RetimerRegInfo | Retimer chip registry information. |
| portal | |
| portal_dfl.log | Information about the portal module. |
| PowerMgnt | |
| power_statistics.csv | Power statistic information. |
| power_bbu_info.log | BBU logs (only for the server that supports BBUs). |
| PowerMgnt_dfl.log | Information about the PowerMgnt module. |
| redfish | |
| component_uri.json | Component URI list. |
| event_sender_info.log | Error notice shown when the Redfish subscription message is sent. |
| redfish_dfl.log | Information about the Redfish module. |
| rimm | |
| rimm_dfl.log | Information about the StorageMgnt module. |
| sensor_alarm | |
| current_event.txt | Current health status and alarms of the server. |
| LedInfo | Current indicator status of the server. |
| sel.db | Database information of the current SELs. |
| sel.tar | Compressed package of current and historical system event logs (SELs). |
| sensor_alarm_dfl.log | Information about the Sensor_Alarm module. |
| sensor_alarm_sel.bin | Original information and check value of the current SELs. |
| sensor_alarm_sel.bin.bak | Original backup information and check value of the current SELs. |
| sensor_alarm_sel.bin.bak.sha256 | Integrity check code for the backup of original SELs. |
| sensor_alarm_sel.bin.sha256 | Integrity check code for original SELs. |
| sensor_alarm_sel.bin.tar.gz | Compressed package of historical SELs. |
| sensor_info.txt | List of all sensors of the server. |
| Smm_Mgnt | |
| Smm_Mgnt_dfl.log | Information about the Smm_Mgnt modules. |
| Snmp | |
| Snmp_dfl.log | Information about the Snmp module. |
| SPDM | |
| spdm_dfl.log | Information on the SPDM module management object. |
| *_import | User-imported SPDM baseline metrics. |
| afm_ca_hash.json | SHA256 value of the stored file. |
| StorageMgnt | |
| PhysicalDrivesInfo | Hard drive history information folder. The sub-folders are named after the hard drives, for example, Disk0\disk_info. NOTE iBMC V3.07.00.77 and later versions can collect this information. |
| RAID_Controller_Info.txt | Information about the RAID controller card, logical drives, and hard drives. |
| StorageMgnt_dfl.log | Information about the StorageMgnt module. |
| switch_card | |
| phy_register_info | Information about the PHY registry of the rear boards. |
| port_adapter_info | Information about the interface device of the rear boards. |
| switch_card_dfl.log | Information about the Switch_Card module. |
| UPGRADE | |
| UPGRADE_dfl.log | Information about the Upgrade module. |
| upgrade_info | Version information about the devices related to the iBMC. |
| User | |
| User_dfl.log | Information about the User module. |
| usb_mgmt | |
| usb_mgmt_dfl.log | Information about the USB module. |
| dump\dump_info\BMALogDump | |
| bma_debug_log bma_debug_log.1.gz bma_debug_log.2.gz bma_debug_log.3.gz | iBMA logs. |
| dump\dump_info\CoreDump | |
| core-* (files starting with "core-".) | Memory dump file. It is the core dump file of an application program. One or more files are generated, depending on the system running status. |
| dump\dump_info\DeviceDump | |
| i2c_info | |
| *_info | I2C device memory or storage area information. |
| dump\dump_info\LogDump | |
| crashdump | |
| crashdump*.tar.gz | FDM TOR logs. NOTE Servers configured with Intel processors support collection of this log information. |
| ras_error_*.cper | Crashdump information when a system error or a system fault occurs. NOTE ● A maximum of 10 latest .cper files can be collected. ● Servers configured with AMD processors support collection of this log information. |
| EyeTest | |
| Eye-Board Name-Switchn.json | PCIe Switch eye diagram test result data. NOTE ● iBMC V3.09.03.01 and later versions can collect this information. ● n indicates the Switch number on the board. |
| M3LogDump | |
| m3_log m3_log.1 …… | M3 logs. |
| netcard | |
| netcard_info.txt netcard_info_bk.txt | NIC configuration information. |
| pciecard | |
| SDI log folder (SDI V3 and earlier versions), named in the SDI card slot number_SDI card name format, for example, pciecard5_IT21SHSG. | ●fw_bios_log.bin: BIOS logs of the SDI card. ●fw_imu_log.bin: Intelligent management unit (IMU) logs of the SDI card. ●fw_last_log.bin: Lastword logs of the SDI card. ●fw_M7_log.bin: M7 logs of the SDI card. |
| The log folder of SDI card (SDI V5.1 version) is named as PCIeCard1(SDIV5.1)_SDI5.1. | ●error_log_SDIV5.1.bin: Log files of SDI card OS. ●error_log_SDIV5.1.bin.1.gz: Log files of SDI card OS in compressed package. |
| sdi_blackbox | SDI black box log folder. NOTE The log information can be collected only after the SDI black box data files have been downloaded from the Diagnostics screen. |
| PCIe card log folder, named in the PCIe card name and slot number_PCIe card model format, for example, "PCIeCard6_SP570". | All PCIe card logs, including CPLD register information, error logs, last words, and preventive maintenance inspection logs. Example: ● cpld.log ● last_word_20160211182849 ● error_log_20160211182532 ● running_log_20160211183202 |
| Retimer | |
| Retimer log folder, which is named after the retimer object. For example, Cdr5902H_Obj_1-10. | Retimer log information, including: ●PCIe: PCIe command output information ●RAMLog: logs exported from the SRAM ●SerDes: SerDes information |
| runtimeerror | |
| dram_runtime_*.cper | Memory error information during system runtime. |
| mca_runtime_*.cper | MCA error information during system runtime. |
| storage | |
| *_com_log *_com_log.1.gz …… | RAID card serial port log, for example, RAID_Card1_com_log. |
| ctrllog | A folder containing all RAID controller cards logs. The sub-folders are named after the RAID controller cards. ●Raw log content of the RAID controller card's AP firmware: "ap.bin". ●Raw log content of the RAID controller card's IMU firmware: "imu.bin". ●Log parsing dictionary of the RAID controller card's AP firmware: "ap_index.gz". ●Log parsing dictionary of the RAID controller card's IMU firmware: "imu_index.gz". ●Raw data of power-off notice of the RAID controller card AP firmware: "lastword.bin". ●Raw data of statistics on the RAID controller card AP firmware: "dump.bin". ●Raw flash data of statistics on the RAID controller card AP firmware: "flash_dump.bin". ●Raw Nand flash log data of the RAID controller card: "0nandlog.bin" and "1nandlog.bin". |
| drivelog | A folder containing all SAS and SATA hard drive logs. The sub-folders are named after the hard drives, for example, Disk0. ●SATA hard drive logs, for example, SATA_Log, SMARTAttribute, SeagateFARMLog ●SAS hard drive logs, for example, SAS_Log and SAS_Log.1 |
| phy | A folder containing PHY error code logs of all RAID controller cards and the expanders on the RAID controller card. The sub- folders are named after the RAID controller cards, for example, RAID_Card1. ●RAID controller card PHY error code log, for example, RAID_Card1_PHY_Error_Count.csv ●Expander PHY error code log, for example, RAID_Card1_Expander1_PHY_Error_ Count.csv |
| storage\storelib | |
| storelib_debug_log storelib_debug_log.1 …… | Storelib library logs. |
| storelib8debug.txt storelib8debug.txt.1 …… | Storelib8 library logs. |
| storelibit_debug_log storelibit_debug_log.1 …… | Storelibit library logs. |
| storelibir3_debug_log storelibir3_debug_log.1 …… | Storelibir3 library logs. |
| dump\dump_info\LogDump | |
| agentless_driver_log agentless_driver_log.1.gz agentless_driver_log.2.gz agentless_driver_log.3.gz …… | Agentless driver debug logs. |
| app_debug_log_all app_debug_log_all.1.gz app_debug_log_all.2.gz app_debug_log_all.3.gz | App Debug logs. |
| bmc_cpu_usage_info.log bmc_cpu_usage_info.log.1.gz | CPU usage information of the BMC (recorded when the CPU usage exceeds 70%). NOTE iBMC V3.07.01.51 and later versions can collect this information. |
| bmccom.dat | BMC serial port log. |
| bmccom_YYYYMMDD-HHmm.dat | BMC serial port log. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off). |
| systemcom_YYYYMMDD- HHmm.dat | SOL serial port information. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off). |
| BMCResetRecord.log | BMC restart record. |
| compliance_prompt_log | Compliance prompt log. |
| config_operate_log config_operate_log.tar.gz | User configuration operation log. NOTE V5/V6 servers support the collection of this log information in iBMC V3.07.03.63 and later versions. V7/V8 servers support this collection by default. |
| corefile | Core dump files. |
| CpuTempLogRecords_CPUn_COR ETEMP.csv CpuTempLogRecords_CPUn_COR ETEMP.csv.1.gz CpuTempLogRecords_CPUn_COR ETEMP.csv.2.gz CpuTempLogRecords_CPUn_COR ETEMP.csv.3.gz | Core temperature of CPUn. The file data format is: timestamp, scan interval (in milliseconds), data1, data2, data3…… NOTE n indicates the CPU number. |
| CpuTempLogRecords_CPUn_MAX MEMTEMP.csv CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.1.gz CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.2.gz CpuTempLogRecords_CPUn_MAX MEMTEMP.csv.3.gz | Maximum temperature of the memory channels of CPUn. The file data format is: timestamp, scan interval (in milliseconds), data1, data2, data3…… NOTE n indicates the CPU number. |
| cpun_m7_log cpun_m7_log.tar.gz | M7 coprocessor run log of CPU (only for the server that supports M7 coprocessor). |
| dfx_log dfx_log.tar.gz | DFX register information. |
| fdm.bin fdm.bin.tar.gz | Log of FDM original faults. |
| fdm_log fdm_log.tar.gz | FDM logs. |
| fdm_me_log fdm_me_log.tar.gz | Log of ME faults. |
| fdm_mmio_log fdm_mmio_log.tar.gz | FDM board configuration logs. |
| fdm_output fdm_output.1.gz fdm_output.2.gz fdm_output.3.gz | FDM logs. |
| fdm_pfae_log | Log of FDM perwarnings. |
| imu_log imu_log.tar.gz | IMU run log (only for the server that supports IMU). |
| ipmi_debug_log ipmi_debug_log.tar.gz | IPMI module logs. |
| ipmi_mass_operate_log ipmi_mass_operate_log.tar.gz | IPMI module operation logs. |
| kvm_vmm_debug_log kvm_vmm_debug_log.tar.gz | KVM module logs. |
| LSI_RAID_Controller_Log LSI_RAID_Controller_Log.1.gz LSI_RAID_Controller_Log.2.gz | Logs of the LSI RAID controller. |
| PD_SMART_INFO_C* | SMART log of hard disks. * indicates the serial number of the RAID controller. |
| linux_kernel_log linux_kernel_log.1 …… | Linux kernel logs. |
| log_records_info-2.csv | Records the number of times the voltage is lower than the alarm threshold. |
| maintenance_log maintenance_log.tar.gz | Maintenance logs. |
| mass_operate_log mass_operate_log.tar.gz operate_log operate_log.tar.gz | User operation log. |
| pcieswcom.dat | PCIe switch logs. NOTE ● G8600 V7 iBMC V3.07.02.25 and later versions support collection of this log information. ● GN560E V7 iBMC V3.08.03.01 and later versions support collection of this log information. |
| PD_SMART_INFO_C0 | SMART information for SATA drives or sense information for SAS drives. |
| preserve.log | Logs of firmware upgrade without configuration retention. |
| ps_black_box.log ps_black_box.log.1.gz ps_black_box.log.2.gz ps_black_box.log.3.gz | Power supply black box logs. |
| remote_log remote_log.1.gz | Operation logs and SEL logs for Syslog test. |
| security_log security_log.1 | Security logs. |
| strategy_log strategy_log.tar.gz | System running logs. |
| telemetry_logservice_offset | Telemetry logservice offset information. |
| telemetryLog | TelemetryLog information. |
| third_party_file_bak.log | Logs of third-party file backup. |
| uart3com.dat | Voice recording file of uart3. |
| uart3com_YYYYMMDD-HHmm.dat | Voice recording file of uart3. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off). |
| uart4com.dat | Voice recording file of uart4. |
| uart4com_YYYYMMDD-HHmm.dat | Voice recording file of uart4. NOTE ● iBMC V3.07.02.61 and later versions can collect this information. ● During the upgrade of mainboard CPLD or VRD, the information is collected automatically after power off (the VRD must supports that the AC takes effect after power off). |
| dump\dump_info\OptPme | |
| pram NOTE This folder contains files from the /opt/pme/pram directory. The files that are not included in this folder are intermediate files generated during the running of the program and have no information security issues. | |
| filelist | List of files in the /opt/pme/pram directory. |
| lost+found | Folder. |
| proc_queue | Process queue ID folder. |
| semid | Process semaphore ID folder. |
| up_cfg | Upgrade configuration folder. |
| BIOS_FileName | SMBIOS information. |
| BIOS_OptionFileName | BIOS configuration information. |
| BMC_dhclient.conf | DHCP configuration file. |
| BMC_dhclient.conf.sha256 | Integrity check code. |
| BMC_dhclient_ip.conf | DHCP configuration file. |
| BMC_dhclient_ip.conf.sha256 | Integrity check code. |
| BMC_dhclient6.conf | DHCP configuration file. |
| BMC_dhclient6.conf.sha256 | Integrity check code. |
| BMC_dhclient6_ip.conf.sha256 | Integrity check code. |
| BMC_HOSTNAME | Host name. |
| BMC_HOSTNAME.sha256 | Integrity check code. |
| cpu_utilise_webview.dat | CPU usage curve data. |
| CpuMem_cpu_utilise | Server CPU usage. |
| CpuMem_mem_utilise | Server memory usage. |
| CpuMem_mem_os_utilise | Server memory usage. |
| env_web_view.dat | Ambient temperature curve data. |
| eo.db | SEL database. |
| fan_speed_webview.dat | Fan speed log. |
| fdm_history.db | FDM health analysis engine database. |
| fdm_history.db.sha256 | Integrity check code. |
| fdm_history.db.sha256_backup | Integrity check code. |
| fdm_history.db_backup | FDM health analysis engine database. |
| filelist | List of files in the /opt/pme/pram directory. |
| fsync_reg.ini | File synchronization configuration file. |
| lost+found | Folder. |
| io_utilise_webview.dat | IO usage curve data. |
| md_so_maintenance_log md_so_maintenance_log.tar.gz | Maintenance logs. |
| md_so_operate_log md_so_operate_log.tar.gz md_so_mass_operate_log md_so_mass_operate_log.tar.gz | User operation log. |
| md_so_operate_log.sha256 | Integrity check code. |
| md_so_strategy_log md_so_strategy_log.tar.gz | Policy log. |
| md_so_strategy_log.sha256 | Integrity check code. |
| memory_os_webview.dat | Memory usage curve data. |
| NetConfig_dhclient.conf | DHCP configuration file. |
| NetConfig_dhclient_ip.conf | DHCP configuration file. |
| per_config.ini | iBMC configuration persistence file. |
| per_config.ini.sha256 | Integrity check code. |
| per_config_permanent.ini | iBMC configuration persistence file. |
| per_config_permanent.ini.sha256 | Integrity check code. |
| per_config_reset.ini | iBMC configuration persistence file. |
| per_config_reset.ini.bak | iBMC configuration persistence file. |
| per_config_reset.ini.bak.sha256 | Integrity check code. |
| per_config_reset.ini.sha256 | Integrity check code. |
| per_def_config.ini | iBMC configuration persistence file. |
| per_def_config.ini.sha256 | Integrity check code. |
| per_def_config_permanent.ini | iBMC configuration persistence file. |
| per_def_config_permanent.ini.sha2 56 | Integrity check code. |
| per_def_config_reset.ini | iBMC configuration persistence file. |
| per_def_config_reset.ini.bak | iBMC configuration persistence file. |
| per_def_config_reset.ini.bak.sha256 | Integrity check code. |
| per_def_config_reset.ini.sha256 | Integrity check code. |
| per_power_off.ini | iBMC configuration persistence file. |
| per_power_off.ini.sha256 | Integrity check code. |
| per_reset.ini | iBMC configuration persistence file. |
| per_reset.ini.bak | iBMC configuration persistence file. |
| per_reset.ini.bak.sha256 | Integrity check code. |
| per_reset.ini.sha256 | Integrity check code. |
| pflash_lock | Flash file lock. |
| PowerMgnt_record | Managed object operating information. |
| powerview.txt | Power statistic file. |
| proc_queue | Process queue ID folder. |
| ps_web_view.dat | Managed object operating information. |
| sel.db | SEL database. |
| sel_db_sync | SEL database synchronization lock. |
| semid | Process semaphore ID folder. |
| sensor_alarm_sel.bin | Original SEL file. |
| sensor_alarm_sel.bin.sha256 | Integrity check code. |
| sensor_alarm_sel.bin.tar.gz | Compressed package of historical SELs. |
| Snmp_http_configure | HTTP configuration folder. |
| Snmp_http_configure.sha256 | Integrity check code. |
| Snmp_https_configure | HTTPS configuration folder. |
| Snmp_https_configure.sha256 | Integrity check code. |
| Snmp_https_tsl | HTTPS TLS configuration folder. |
| Snmp_https_tsl.sha256 | Integrity check code. |
| Snmp_snmpd.conf | Snmp configuration backup file |
| Snmp_snmpd.conf.sha256 | Integrity check code. |
| up_cfg | Upgrade configuration folder. |
| User_login | Login PAM login rules. |
| User_login.sha256 | Integrity check code. |
| User_sshd | SSH PAM login rules. |
| User_sshd.sha256 | Integrity check code. |
| User_sshd_config | SSH configuration file. |
| User_sshd_config.sha256 | Integrity check code. |
| User_vsftp | FTP PAM login rules. |
| User_vsftp.sha256 | Integrity check code. |
| save NOTE This folder contains files from the /opt/pme/save directory. The *.sha256 file contains the integrity check code. The *.bak file is the backup file. The *.tar.gz file is a compressed file package. The per_*.ini file is a configuration persistence file. The *sel.* is a system event log file. (The files that are not included in this folder are intermediate files generated during the running of the program and have no information security issues.) | |
| filelist | List of files in the /opt/pme/pram directory. |
| BIOS_FileName | SMBIOS information. |
| BMC_dhclient.conf.bak | DHCP configuration backup file. |
| BMC_dhclient.conf.bak.sha256 | Integrity check code. |
| BMC_dhclient.conf.sha256 | Integrity check code. |
| BMC_dhclient_ip.conf.bak | DHCP configuration backup file. |
| BMC_dhclient_ip.conf.bak.sha256 | Integrity check code. |
| BMC_dhclient_ip.conf.sha256 | Integrity check code. |
| BMC_dhclient6.conf.bak | DHCP configuration backup file. |
| BMC_dhclient6.conf.bak.sha256 | Integrity check code. |
| BMC_dhclient6.conf.sha256 | Integrity check code. |
| BMC_dhclient6_ip.conf.bak | DHCP configuration backup file. |
| BMC_dhclient6_ip.conf.bak.sha256 | Integrity check code. |
| BMC_dhclient6_ip.conf.sha256 | Integrity check code. |
| BMC_HOSTNAME.bak | Host name configuration backup file. |
| BMC_HOSTNAME.bak.sha256 | Integrity check code. |
| BMC_HOSTNAME.sha256 | Integrity check code. |
| CpuMem_cpu_utilise | Managed object operating information. |
| CpuMem_mem_utilise | Managed object operating information. |
| eo.db | SEL database. |
| eo.db.sha256 | Integrity check code. |
| eo.db.sha256_backup | Integrity check code. |
| eo.db_backup | SEL database. |
| fdm_history.db | FDM health analysis engine database. |
| fdm_history.db.sha256 | Integrity check code. |
| fdm_history.db.sha256_backup | Integrity check code. |
| fdm_history.db_backup | FDM health analysis engine database. |
| filelist | List of files in the /opt/pme/pram directory. |
| md_so_config_operate_log.bak | User configuration operation log. |
| md_so_config_operate_log.bak.sha 256 | Integrity check code. |
| md_so_config_operate_log.sha256 | Integrity check code. |
| md_so_operate_log.bak | User operation log |
| md_so_operate_log.bak.sha256 | Integrity check code. |
| md_so_operate_log.sha256 | Integrity check code. |
| md_so_strategy_log.bak | Policy log. |
| md_so_strategy_log.bak.sha256 | Integrity check code. |
| md_so_strategy_log.sha256 | Integrity check code. |
| NetConfig_dhclient.conf.bak | DHCP configuration backup file. |
| NetConfig_dhclient_ip.conf.bak | DHCP configuration backup file. |
| per_config.ini | iBMC configuration persistence file. |
| per_config.ini.bak | iBMC configuration persistence file. |
| per_config.ini.bak.sha256 | Integrity check code. |
| per_config.ini.sha256 | Integrity check code. |
| per_def_config.ini | iBMC configuration persistence file. |
| per_def_config.ini.bak | iBMC configuration persistence file. |
| per_def_config.ini.bak.sha256 | Integrity check code. |
| per_def_config.ini.sha256 | Integrity check code. |
| per_power_off.ini | iBMC configuration persistence file. |
| per_power_off.ini.bak | iBMC configuration persistence file. |
| per_power_off.ini.bak.sha256 | Integrity check code. |
| per_power_off.ini.sha256 | Integrity check code. |
| PowerMgnt_record | Managed object operating information. |
| sensor_alarm_sel.bin | Original information and check value of the current SELs. |
| sensor_alarm_sel.bin.bak | Original information and check value of the current SELs. |
| sensor_alarm_sel.bin.bak.sha256 | Integrity check code. |
| sensor_alarm_sel.bin.sha256 | Integrity check code. |
| sensor_alarm_sel.bin.tar.gz | Compressed package of historical SELs. |
| Snmp_http_configure.bak | HTTP configuration backup file. |
| Snmp_http_configure.bak.sha256 | Integrity check code. |
| Snmp_http_configure.sha256 | Integrity check code. |
| Snmp_https_configure.bak | HTTPS configuration backup file. |
| Snmp_https_configure.bak.sha256 | Integrity check code. |
| Snmp_https_configure.sha256 | Integrity check code. |
| Snmp_https_tsl.bak | HTTPS TLS configuration backup file. |
| Snmp_https_tsl.bak.sha256 | Integrity check code. |
| Snmp_https_tsl.sha256 | Integrity check code. |
| Snmp_snmpd.conf.bak | Snmp configuration backup file. |
| Snmp_snmpd.conf.bak.sha256 | Integrity check code. |
| Snmp_snmpd.conf.sha256 | Integrity check code. |
| User_login.bak | Login PAM login rules |
| User_login.bak.sha256 | Integrity check code. |
| User_login.sha256 | Integrity check code. |
| User_sshd.bak | SSH PAM login rules |
| User_sshd.bak.sha256 | Integrity check code. |
| User_sshd.sha256 | Integrity check code. |
| User_sshd_config.bak | SSH configuration file. |
| User_sshd_config.bak.sha256 | Integrity check code. |
| User_sshd_config.sha256 | Integrity check code. |
| User_vsftp.bak | FTP PAM login rules |
| User_vsftp.bak.sha256 | Integrity check code. |
| User_vsftp.sha256 | Integrity check code. |
| dump\dump_info\OSDump | |
| *.rep | Video files automatically recorded. NOTE If a video file exceeds 21 MB, you are advised to download and save it to the local PC. The iBMC will delete the video file larger than 21 MB during one-click information collection. |
| bsod_auto.jpeg | OS screenshot. |
| img*.jpeg | Image of the last screenshot of the server OS. |
| systemcom.tar | SOL serial port information. |
| video_caterror_rep_is_deleted.info | Information prompting users to delete oversized caterror video files. |
| dump\dump_info\Register | |
| cpld_reg_info | Complex programmable logical device (CPLD) register information. |
| xxx_xxx_cpld_reg_info | Information about CPLD registers. The file naming format is device type_device name_cpld_reg_info. For example, Disk_BP3BC15HBBA_cpld_reg_info. (Including midplane and module.) |
| lsw_reg_info | Information about LSW registers. |
| phy_reg_info | Information about PHY registers. |
| cpu_reg_info | CPU register information. |
| oem_sensor_info | Secondary sensor information file. |
| vrm_reg_info | Information about VRM registers. |
| dump\dump_info\RTOSDump | |
| driver_info | |
| cdev_drv_info | The statistics of character device driver. |
| dmesg_info | System startup information (execution result of dmesg). |
| edma_drv_info | The statistics of edma driver. |
| kbox_info | kbox information. |
| lsmod_info | Information about loaded drivers. |
| veth_drv_info | The statistics of virtual network card driver. |
| networkinfo | |
| _data_var_dhcp_dhclient.leases | DHCP lease file. |
| dhclient.conf | DHCP configuration file. |
| dhclient.leases | DHCP lease file. |
| dhclient_ip.conf | DHCP configuration file. |
| dhclient6.conf | DHCP configuration file. |
| dhclient6.leases | DHCP lease file. |
| dhclient6_eth0.leases | DHCP lease file. |
| dhclient6_eth1.leases | DHCP lease file. |
| dhclient6_eth2.leases | DHCP lease file. |
| dhclient6_ip.conf | DHCP configuration file. |
| ifconfig_info | Network information. You can run the ifconfig command to obtain it. |
| ipinfo_info | iBMC network configuration information. |
| netstat_info | netstat -a Displays the current network ports and connection status. |
| resolv.conf | DNS configuration file. |
| route_info | route Displays the current routing information. |
| services | Service port information. |
| other_info | |
| datafs_log | The data check log. |
| extern.conf | iBMC log file configuration. |
| login | Login PAM login rules. |
| logrotate.status | File recording the logrotate status. |
| ntp.conf | NTP service configuration. |
| pam_faillock | PAM error message. |
| pam_tally2 | User lockout policy upon an iBMC login failure. |
| remotelog.conf | Syslog configuration file. |
| ssh | SSH service configuration. |
| sshd | SSH PAM login rules. |
| sshd_config | SSHD service configuration file. |
| vsftpd | FTP PAM login rules. |
| sysinfo | |
| cmdline | Kernel command line parameters. |
| cpuinfo | Information about the CPU chip of the iBMC kernel. |
| devices | iBMC device information. |
| df_info | Information about the usage of the iBMC partitions. |
| diskstats | Information about the iBMC drive status. |
| filesystems | iBMC file system information. |
| free_info | Information about available iBMC memory. |
| interrupts | iBMC interrupt information. |
| ipcs_q | iBMC process queue information. |
| ipcs_q_detail | Detailed information about the iBMC process queue. |
| ipcs_s | iBMC process semaphore information. |
| ipcs_s_detail | Detailed information about the iBMC process semaphore. |
| loadavg | iBMC system workload information. |
| locks | List of iBMC kernel lock files. |
| meminfo | iBMC memory usage information. |
| modules | List of iBMC modules. |
| mtd | Information about the iBMC configuration partition. |
| partitions | Information about the iBMC partitions. |
| ps_info | ps -elf Displays detailed information about iBMC processes. |
| slabinfo | Information about the iBMC slab information. |
| stat | CPU usage of the iBMC. |
| top_info | top -bn 1 Displays the current process running information. |
| uname_info | uname -a Displays current status of the iBMC processes. |
| uptime | iBMC system operating time |
| version | Real-time operating system (RTOS) version of the iBMC. |
| vmstat | iBMC virtual memory statistical information. |
| versioninfo | |
| app_revision.txt | iBMC version information. |
| build_date.txt | Time when the iBMC version was built. |
| fruinfo.txt | FRU electronic label information. |
| ibmc_revision.txt | iBMC revision information. |
| RTOS-Release | RTOS release information. |
| RTOS-Revision | RTOS version markup. |
| server_config.txt | Current configuration information of the server. |
| dump\dump_info\SpLogDump NOTE The logs cannot be collected during the SP running process. | |
| iBMALogDump | iBMA log folder. |
| config | This log information can be collected only after the SP is running. NOTE The logs can be collected after the configuration is exported on the SP. |
| upgrade | Firmware upgrade log folder. |
| component_version.json | Configuration file of the Smart Provisioning component package version. |
| deviceinfo.json | Server asset information. |
| diagnose | Hardware diagnostics log. NOTE The logs can be collected after hardware diagnosis is performed on the SP. |
| dmesg.log dmesg.tar.gz | dmesg logs of the small system. |
| SPCfglog.tar.gz | SPCfg log. NOTE The logs can be collected after the configuration is exported on the SP. |
| filepatchup_debug.log | Quick deployment file packaging logs. NOTE The logs can be collected after SP quick deployment is performed. |
| images.log | Quick deployment clone logs. NOTE The logs can be collected after SP quick deployment is performed. |
| images_restore.log | Quick deployment rollback logs. NOTE The logs can be collected after SP quick deployment is performed. |
| maintainlog.csv maintainlog.tar.gz | SP maintenance log. The maintainlog files with timestamps are logs collected earlier. |
| operatinglog.csv | SP operating log. The operatinglog files with timestamps are logs collected earlier. |
| ping6.log ping6.tar.gz | Network communication logs. |
| quickdeploy_debug.log | Quick deployment logs. NOTE The logs can be collected after SP quick deployment is performed. |
| rollback_version.ini | Version that supports component package rollback. |
| sp_upgrade_info.log | SP self-upgrade logs. NOTE The logs can be collected after SP self-upgrade is performed. |
| upgrade.log | SP firmware update logs. |
| upgrade_result.json | Upgrade result logs. |
| varmesg.log syslog.tar.gz | Small system information logs. |
| version.json | SP version information. |
| version.json.* | Verification file of the SP version configuration file. |
6.8.17 Performing One-Click Information Collection (diaginfo)
Function
The diaginfo command is used to collect information in one-click mode, including iBMC configuration information, version information, and logs. For more details, see 5.10 One-Click Information Collection.
Format
ipmcget -d diaginfo
Parameters
None
Usage Guidelines
To view the collected information, use a file transfer tool that supports SFTP, for example WinSCP, to transfer the file (for example dump_info.tar.gz) from the /tmp directory to the local PC.
Example
# Perform one-click information collection.
iBMC:/->ipmcget -d diaginfo Downloading... 100% Download diagnose info to /tmp/ successfully.