IBM Power Small Systems Preventive Maintenance (Inspection) Report

IBM Power Server Preventive Maintenance (Inspection) Report

IBM Power System Preventative Maintenance Report

User Name

Customer

Contact Person

Contact

Phone Number

Phone

Arrival Time

Arival

Departure Time

Departure

Maintenance Type

Reqair Class

Product Model

Product No.

Serial Number

Serial No.

Physical Equipment Inspection

Inspection Item

Inspection Result

Description

1

Is the control panel fault light on?

□ Yes □ No

2

Are the hard drive status lights abnormal?

□ Yes □ No

3

Are the network card and Fibre Channel card status lights abnormal?

□ Yes □ No

4

Is the fan air outlet state abnormal?

□ Yes □ No

5

Does the equipment make any unusual noises?

□ Yes □ No

6

Is the chassis exterior overheating?

□ Yes □ No

7

Is the power cord connection loose?

□ Yes □ No

8

Check if FC fiber optic cables and ENC connections are excessively bent.

□ Yes □ No

9

Are there hardware error messages in ASMI?

□ Yes □ No

10

Are there deconfigured resources in ASMI?

□ Yes □ No

11

Are there issues with the data center environment?

□ Yes □ No

12

Are there any other abnormal conditions?

□ Yes □ No

Equipment System Check

Inspection Item

Inspection Result

Description

1

Is there a system error report (Error Log)?

□ Yes □ No

errpt|more

2

Is there an error report sent to the root user?

□ Yes □ No

mail

3

Check for logical volumes in stale state

□ Yes □ No

lsvg -o; lsvg -l vgname or lsvg vgname

4

Check hacmp.out, smit.log, bootlog, etc.

□ Normal □ Abnormal

/tmp/hacmp.out; smit.log; alog -o -t boot

5

Is key file system usage greater than 80%?

□ Yes □ No

df -g

6

Does page space usage exceed 70%?

□ Yes □ No

lsps -a; lsps -s

7

Is the swap space size setting unreasonable?

□ Yes □ No

vmstat; lsps -a

8

Does the tape drive require cleaning?

□ Yes □ No

9

Communication: Network interface card status, IP address, routing table

□ Normal □ Abnormal

netstat -i; netstat -rn ; entstat -a ent*

10

Network interface card communication (Ping)

□ Normal □ Abnormal

ping ip address

11

Is the system dump setting normal?

□ Normal □ Abnormal

sysdumpdev -l; sysdumpdev -e

12

Is the hard disk boot setting normal?

□ Normal □ Abnormal

bootlist -m normal -o

13

Is HACMP status normal?

□ Normal □ Abnormal

lssrc -g cluster; /usr/sbin/cluster/clstat -a

14

Is the storage link status normal?

□ Normal □ Abnormal

datapath query adapter or powermt display

15

Is there a compliant system backup?

□ Yes □ No

16

Is there a data protection method such as RAID10/RAID5?

□ Yes □ No

17

Are system parameters correct:

1) TZ in /etc/environment has no Daylight Saving Time

2) If a database system exists: Aio:available

3) In Hacmp system: syncd:10

□ Yes □ No

more /etc/environment

lsdev -Cc aio

smit hacmp

18

Is the hard disk status active?

□ Yes □ No

lsvg -p rootvg

19

Is rootvg mirrored?

□ Yes □ No

lsvg -l rootvg

20

Is CPU guard enabled?

□ Yes □ No

lsattr -El sys0 |grep cpuguard

21

Does the system reboot after an AIX crash?

□ Yes □ No

lsattr -El sys0 |grep autorestart

22

Are there no performance bottlenecks in the system?

□ Yes □ No

vmstat; topas

23

Is snap -gc captured for further inspection?

□ Yes □ No

snap -r; snap -gc

24

Operating System Version: _____________________

oslevel -s

25

System Microcode Version: _____________________

lsmcode

26

HACMP Version: _____________________

lslpp -l |grep cluster

Inspection Results, Confirmation and Signature

Preventive Maintenance Result:

Opinions and Suggestions on Preventive Maintenance:

Customer Signature

Customer Sign

Engineer Signature

Engineer Sign

Date

Date

11 views Updated 2026-11-07