Oracle Exadata Daily Maintenance: Emergency Response Plan
Exadata Daily Maintenance Manual
Emergency Response Plan
Exadata Emergency Response Personnel
Name | Responsibilities | Contact Information |
Fault Scenario One
Scenario Description
A hard drive on the Exadata Appliance Data Server (DB server) has failed.
Handling Steps
Since the Exadata Appliance itself has RAID protection, the hard drive can be replaced directly without shutting down the system. No shutdown operation is required.
Check disk status information via the raid command
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL | grep "Device Present" -A 8
Use the machine's iLOM port to further diagnose the data server failure and determine the location of the faulty drive.
After collecting all information, log in to support.oracle.com to submit a service request for the Exadata Appliance, requesting maintenance services for the Exadata Appliance.
Oracle support personnel will replace the faulty hard drive based on the relevant information.
Result Verification
After replacement, use the following command to check if the status of the replaced hard drive is normal.
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL | grep "Device Present" -A 8
Use the following command to check the synchronization status of the data devices
/opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog -physdrv \
[disk_enclosure:slot_number] -a0
Fault Scenario Two
Scenario Description
The Exadata Appliance PDU or InfiniBand switch has a single fault
Handling Steps
Since the equipment adopts a dual-redundancy structure, a failure of a single PDU or InfiniBand switch will not affect the operation of the Exadata Appliance.
Monitor Exadata using EM 13C software; if an alarm occurs for the PDU or InfiniBand switch, collect fault information.
After collecting all information, log in to support.oracle.com to submit a service request for the Exadata Appliance, requesting maintenance services for the Exadata Appliance.
Based on the fault situation, Oracle support personnel will configure or replace the faulty PDU or InfiniBand switch.
Result Verification
Monitor Exadata using EM 13C software; after the fault is resolved, alarms for the PDU or InfiniBand switch will be automatically cleared.
Fault Scenario Three
Scenario Description
A hard drive on the Exadata Appliance Storage Server (Cell Server) has failed.
Handling Steps
Monitor Exadata using EM 13C software. After detecting an alarm for the Exadata Storage Server (Cell Server), use the following command to check the hard drive fault status.
CellCLI> LIST PHYSICALDISK WHERE diskType=HardDisk AND status=failed DETAILname: 28:5
deviceId: 21
diskType: HardDisk
enclosureDeviceId: 28
errMediaCount: 0
errOtherCount: 0
foreignState: false
luns: 0_5
makeModel: "SEAGATE ST360057SSUN600G"
physicalFirmware: 0705
physicalInterface: sas
physicalSerial: A01BC2
physicalSize: 558.9109999993816G
slotNumber: 5
status: failed
Go to the faulty server, locate the failed hard drive, retrieve a spare hard drive from the warehouse, and prepare to replace the faulty hard drive.
Remove the faulty hard drive, wait for a few minutes, then insert the new hard drive into the corresponding slot.
Use the following command to check and confirm that the hard drive status is Normal.
CellCLI> LIST PHYSICALDISK WHERE name=[enclosureDeviceId:slotNumber] ATTRIBUTES statusResult Verification
Server hard drive alarm cleared, EM13C monitoring software fault cleared
Use relevant commands to check and confirm that the hard drive status is Normal.
Fault Scenario 4
Scenario Description
A flash card failure occurs on an Exadata Machine Storage Server (Cell Server).
Handling Steps
After monitoring the Exadata system with EM 13C software and detecting a fault alert for the Exadata Storage Server (Cell Server), check the disk fault status using the following command:
CellCLI> LIST PHYSICALDISK WHERE diskType=flashdisk AND status=failed DETAILPut all grid disks into inactive state
CELLCLI> Alter GRIDDISK ALL INACTIVEVerify that all grid disks are in inactive state
CELLCLI> LIST GRIDDISK WHERE STATUS !=’inactive’Stop Cell services
CellCLI> ALTER CELL SHUTDOWN SERVICES ALLShut down the faulty storage server
Retrieve a spare flash card from the warehouse to prepare for replacing the faulty flash card.
After replacement, restart the Exadata Storage Server (Cell Server).
Put all grid disks into active state
CELLCLI> ALTER GRIDDISK ALL ACTIVEVerify that all grid disks are in active state
CELLCLI> LIST GRIDDISK ATTRIBUTES name , asmmodestatusAfter restart, the new Flash card will be automatically recognized and used by the system.
Result Verification
Server disk alerts are cleared; EM13C monitoring software fault is resolved.
Fault Scenario 4
Scenario Description
Exadata Machine database query/update anomalies occur, such as slow query/update speeds or freezing.
Handling Steps
Monitor the Exadata system operation using EM13C software to identify data processing bottlenecks.
Collect AWR reports, submit them to the Oracle ACS team for analysis, and quickly resolve the fault.
Result Verification
Exadata Machine query/update operations return to normal.